background image

45

GB

The stove does not 
turn on automatically

1. The tank is empty.
2. The resistance does not reach 
the temperature
3. Resistance damaged
4. The pellet drops
5. Screw motor defective
6. The grate is not in place or is 
dirty
7. Obstruction of nests or foreign 
bodies in the chimney or fire-
place
8. Check operation of the glow 
plug
9. The ash drawer is not closed 
properly
10. Clogged flue and chimney
11. Smoke extractor not working
12. Temperature sensor defective
13. Pellet wet

1. Fill the tank with pellets
2. Check the electrical wiring and fuses, replace if 
the resistance is broken
3. Replace the resistance
4. It is recommended to unplug the power supply 
before:
- check that the pellet is not caught in the chute
- check that the cochlea is not blocked by dirt
- check the seal of the pellet-door

5. Contact an authorized service center

6. Check that the hole in the brazier matches the 
glow plug, clean brazier
7. Remove any foreign body from the chimney or flue 
pipe
8. Make sure that there is power. Replace the spark 
plug if burned
9. Close the drawer ashtray
10. Perform periodic cleaning

11. Check the operation of the extractor flue
12. Contact an authorized service center

13. Make sure the place of stowage pellet and re-
place it with a handful of dry pellets

Lock the stove.
Pellets not being fed 
into the combustion 
chamber

1. The tank is empty
2. The cochlea is no pellet
3. Technical problem of the 
cochlea
4. Reduction motor failure
5. Electronic board faulty

1. Load the pellets in the tank.
2. Fill the tank and proceed as instructed before igni-
tion stove
3. IT IS RECOMMENDED to unplug the power sup-
ply before:
- empty the thank and manually free the auger from 
obstructions (sawdust)
- release the slide from obstructions
- remove the dust accumulation of pellets in the bot-
tom of the tank

4. Replace the reduction motor
5. Replace the electronic board

The stove runs for a 
few minutes and then 
turn off

1. Lighting cycle not completed
2. Temporary failure of electricity
3. Probes fumes defective or 
broken or not inserted

1. Re-run power
2. Re-run power

3. Check and replace sensors

Fume extraction fan 
does not stop

1. The stove has not yet cooled

1. Allow the stove to cool. Only after cooling fan will 
stop. 

If the problem persists, contact your author-

ized service center

Summary of Contents for Mignon 6

Page 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Page 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Page 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Page 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Page 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Page 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Page 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Page 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Page 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Page 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Page 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Page 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Page 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Page 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Page 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Page 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Page 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 25: ...48 GB NOTES Cod 001124...