It is necessary to daily clean the brazier 
and often clean the ash box. The lack of 
cleanliness can prevent the starting of the 

stove, causing damages to the stove itself and to 
the environment (possible emission of unbrunt 
material and soot). Do not re-use the pellet possibly 
remained in the brazier due to no starting-up.

2

1

CLEANING BY THE TECHNICAL

Check every year

Clean the combustion chamber

Remove the brazier and clean it of any residue. (photo 1)

Remove  the  central  screw  that  holds  the  combustion 
chamber. (photo 2)
Remove the walls of the combustion chamber and clean 
the residue remaining behind this wall. (photo 3)

3

• remove the electrical feed cable;
• remove the cap from the T-joint and proceed with the 
cleaning of the ducts. If necessary, at least for the first few 
times, call in qualified personnel;
•  carefully  clean  the  smoke  discharge  system:  for  this, 
contact a professional chimney sweep;
• once a year clean the dust, cobwebs, etc. from the zone 
behind  the  internal  covering  panels,  paying  particular 
attention to the fans.

Cleaning the fans

The  stove  is  furnished  with  fans  (environmental  and 
smoke) positioned at the rear and below the stove.
Eventual  deposits  of  dust  or  ash  on  the  blades  of  the 
fan can cause an imbalance in the fans leading to noisy 
performance. It is, therefore, necessary to clean the fans 
at least once a year.
Since said operation requires dismantling several parts of 
the  stove,  have  the  fans  cleaned  only  by  our  Technical 
Assistance Centre. 

Season end cleaning

At the end of the season, when the stove will not be used 
for some time, it is advisable to perform a thorough and 
general cleaning: 
• Remove all the pellets from the container and the screw 
feeder;
•  Carefully  clean  the  brazier,  the  brazier  support,  the 
combustion chamber and the ash box.

Once  the  preceding  points  have  been  observed,  it  only 
means that the state of the stove has been verified. It is 
necessary to thoroughly clean the smoke discharge tube 
or flue and check the condition of the basket.
If  necessary,  order  a  new  one  from  our  Authorized 
Assistance Centre.
If  necessary,  lubricate  the  hinges  of  the  door  and  the 
handle. Also check the ceramic fibre cord near the glass, 
on  the  internal  wall  of  the  door;  if  it  is  worn  or  too  dry, 
order a new one from the Authorized Assistance Centre.

Cleaning the clearing system

Until  a  reasonable  experience  is  acquired  regarding 
the  operating  conditions,  it  is  advisable  to  perform  this 
maintenance on at least a monthly basis.

Summary of Contents for Mignon 6

Page 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Page 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Page 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Page 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Page 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Page 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Page 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Page 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Page 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Page 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Page 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Page 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Page 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Page 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Page 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Page 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Page 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 25: ...48 GB NOTES Cod 001124...