background image

853653-1004J

MODEL: VG1820

United States Stove Company

PO Box 151, 227 Industrial Park Rd.,

South Pittsburg, TN 37380

PH: (800) 750-2723

www.usstove.com

SAFETY NOTICE:

If this heater is not properly installed, a house fire may result. 

For  your  safety,  follow  the  installation  instructions.  Never 

use make-shift compromises during the installation of this 

heater. Contact local building or fire officials about permits, 

restrictions and installation requirements in your area.

CAUTION!

Please read this entire manual before you install or use your 

new room heater. Failure to follow instructions may result in 

property damage, bodily injury, or even death. Improper 

Installation Could Void Your Warranty!

Save  These  Instructions.  This  manual  will  help  you  to  obtain 

efficient, dependable service from the heater, and enable 

you to order repair parts correctly. Keep in a safe place for 

future reference.

U.S. Environmental Protection Agency 

Certified to comply with 2020 

particulate emissions standards.

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

Do  not  install  this  heater  in  a  mobile 

home or trailer.

R

Report Number: F19-552

This manual is subject to change without notice.

ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES 

ONLY.  ACTUAL  PRODUCT  MAY  VARY  DUE  TO  PRODUCT 

ENHANCEMENT.

Tested  Per  EPA  Methods  ALT-125,  ASTM 

E2515, ASTM E3053 and CSA B415

Certified to: UL 1482-2011 (R2015), ULC-

628-93

Summary of Contents for VOGELZANG VG1820

Page 1: ...p in a safe place for future reference U S Environmental Protection Agency Certified to comply with 2020 particulate emissions standards CALIFORNIA PROPOSITION 65 WARNING This product can expose you t...

Page 2: ...a UL 103 HT U S Listed Residential Type and Building Heating Appliance Chimney Use a 6 diameter chimney that is high enough to create sufficient draft 11 Be sure your chimney is safely constructed and...

Page 3: ...ning Systems for Existing Masonry or Factory Built Chimneys and Vents or CAN ULC S640 Standard for Lining Systems for New Masonry Chimneys 24 Permanently seal any opening between the masonry of the fi...

Page 4: ...acement if the appliance is ever removed The removal of any parts that render the fireplace unusable for burning solid fuel requires a permanent label to be affixed by the installer that states the fi...

Page 5: ...ng fuel fired equipment shows evidence of back puffing smoke roll out inefficient operation or excessive smell in the living area b Opening a window or door alleviates any of the above problems or sym...

Page 6: ...e with a metal warning label Permanently attach the warning plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by scre...

Page 7: ...your stove and radiates heat more evenly If firebricks were removed to position appliance replace them before firing appliance See figure 7 for proper orientation and positioning Install the back row...

Page 8: ...must meet the three minimum height requirements detailed in figure 8 A minimum draft of 0 05 w c measured in water column is required for proper drafting to prevent back puffing smoke spillage and to...

Page 9: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Page 10: ...chemicals or waste in this appliance could result in damages to the heater or result in bodily injury It will also void any warranty on the appliance This heater is designed to burn natural wood only...

Page 11: ...he best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the c...

Page 12: ...ance overfiring is when any part of the appliance s exterior or chimney connections glow 5 Close the feed door and secure tightly 6 Adjust the air inlet control as described in the Fueling Instruction...

Page 13: ...ng green wood may cause excessive creosote build up Ignition of creosote or overfiring could cause a chimney fire Chimney fires burn extremely hot and may ignite surrounding combustible materials In c...

Page 14: ...inal disposal The ashes should be retained in the closed container until all cinders have thoroughly cooled SMOKE AND CO MONITORS Burning wood naturally produces smoke and carbon monoxide CO emissions...

Page 15: ...t from glass clip 4 Remove old gasket and clean glass 5 Replace new gasket starting at the bottom of glass working along edges being sure to center gasket channel on glass 6 Trim to length and butt en...

Page 16: ...CORD NEAR OR ACROSS HOT SURFACES CAUTION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE MALE BLACK BLACK BLACK WHITE BLACK WHITE MALE B...

Page 17: ...2 3 12 11 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER USE OF THIRD PARTY COM...

Page 18: ...2 12 29230 Gasket Clamp 1 In Order To Maintain Warranty Components Must Be Replaced Using Original Manufacturers Parts Purchased Through Your Dealer Or Directly From The Appliance Manufacturer Use Of...

Page 19: ...19 Notes...

Page 20: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 21: ...ult rieure Lors d une correspondance donnez toujours le num ro de mod le complet qui est inscrit sur la plaque attach e l appareil de chauffage Lors de la commande de pi ces de rechange donnez toujour...

Page 22: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 23: ...tenir la garantie les composants doivent tre remplac s par des pi ces d origine achet es chez votre revendeur ou directement aupr s du fabricant de l appareil L utilisation de composants tiers annuler...

Page 24: ...4 611008 Cabinet droit 1 5 893261 Glissi re d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 10 1 13 8 15...

Page 25: ...sur des surfaces chaudes Mise en garde Le ventilateur doit tre d connect de la source d alimentation lectrique avant de tenter toute op ration de maintenance M le Noire Noire Noire Blanche Noire Blanc...

Page 26: ...r une tanch it correcte si les cordons deviennent effiloch s ou us s remplacez les tout de suite La porte ce cette unit utilise un joint de corde de 1 po de diam tre LE REMPLACEMENT DU CORDON D TANCHE...

Page 27: ...t naturellement des missions de fum e et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait des concentrations lev es pour une p riode de temps prolong e Bien que les syst...

Page 28: ...ance calorifique d passant les sp cifications de conception du chauffage peut lui causer des dommages permanents ainsi qu au catalyseur de postcombustion s il est pr sent 7 Videz les cendres r guli re...

Page 29: ...les b ches rouler et heurter la vitre REMARQUE Ne surchauffez pas l appareil une surchauffe se produit lorsqu une partie des connexions ext rieures ou de la chemin e de l appareil brille 5 Fermez la p...

Page 30: ...n bon feu un taux de combustion inf rieur peut tre une meilleure option pour un chauffage efficace Un taux de combustion inf rieur ralentit le flux de chaleur utilisable hors de la maison par la chemi...

Page 31: ...aibles r sultent g n ralement lors de la combustion de bois durs s ch s s ch s l air par rapport aux r sineux ou aux bois durs verts ou fra chement coup s NE PAS BR LER 1 Des ordures 2 Coupures de gaz...

Page 32: ...m me pourrir au lieu de s cher On ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avai...

Page 33: ...ges de dos les d versements de fum e et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de po les et sont conomiques louer ou acheter De...

Page 34: ...r l appareil Voir figure 7 pour la bonne orientation et le positionnement correct Installez en premier la rang e de briques situ e l arri re suivie par celle de chaque c t et enfin les briques r fract...

Page 35: ...marquer et pr percer les trous n cessaires pour fixer l tiquette 7 Positionnez l appareil dans l ouverture du foyer jusqu ce que la l vre sup rieure de la chemise d air soit align e avec la fa ade du...

Page 36: ...sommet de la chemin e est exig Un adaptateur en acier inoxydable est recommand pour attacher la gaine conduit d acier inoxydable la buse La partie m le ou ondul e de l adaptateur doit tre install e l...

Page 37: ...doivent tre stock es pr cautionneusement si l appareil est d plac Le d montage de n importe quelle pi ce qui rend la chemin e inutilisable pour br ler des combustibles solides implique qu une tiquett...

Page 38: ...x sp cifications CAN ULC S635 Classe 3 norme pour les conduits existants de chemin es industrielles ou de ma onnerie ou CAN ULC S640 norme pour les conduits de nouvelles chemin es de ma onnerie 24 Sce...

Page 39: ...e autre pi ce un espace confin le grenier ou l int rieur d un b timent Ne connectez pas cet appareil un conduit de chemin e d j utilis par un autre appareil 10 NE connectez pas un appareil de chauffag...

Page 40: ...piers pour plus d informations sur les conditions d installation et les restrictions N utilisez pas cet appareil dans un mobile home une maison pr fabriqu e une caravane ou une tente U S Environmental...

Reviews: