background image

* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.

© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 

Ph. 800-750-2723

THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.

Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency 

Certified  to  comply  with  2020  particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. 
For  your  safety,  follow  the  installation  instructions.  Never  use  make-shift 

compromises during the installation of this heater. Contact local building or 

fire officials about permits, restrictions and installation requirements in your 

area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.

CAUTION! Please read this entire manual before you install or use your new room 
heater. Failure to follow instructions may result in property damage, bodily injury, 

or even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon 
monoxide, which is known to the State of California to cause 
cancer, birth defects, and/or other reproductive harm. For 
more information, go to

 www.P65warnings.ca.gov

AP5780

852925K-0204K

R

Report Number: F19-550

Certified  to  ASTM  E1509-12  (2017) 

and Certified to ULC S627-00-REV1

Mobile Home Approved

Model Number:

Summary of Contents for AP5780

Page 1: ...e officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Re...

Page 2: ...l 1 800 750 2723 Ext 5050 or Text to 423 301 5624 or Email us at customerservice usstove com Note Register your product online at www usstove com or download the free app today This app is available only on the App Store for iPhone and iPad Search US Stove Save your receipt with your records for any claims Your pellet stove has been approved for installation in the USA and Canada It may also be in...

Page 3: ... Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual...

Page 4: ... as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL 800 750 2723 EXT 5050 ...

Page 5: ...PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERL...

Page 6: ... 6 153 mm CAN 8 204 mm C Front to Stove U S A 6 153 mm CAN 8 204 mm D Back and Sides to Flue 6 153 mm CLEARANCES Your pellet stove has been tested and listed for installation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrictions Any reduction in clearance to combustibles may only be done by means ap...

Page 7: ...he mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside air is mandatory for mobile home installation See Outside Air Supply section and your dealer for purchasing Check with your local building officials as other codes may apply VENTING REQUIREMENTS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER DO NOT CONNECT THE PEL...

Page 8: ...ased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential by 30 to 50 All joints in the vent system must be fastened by at least 3 screws a...

Page 9: ... or one every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to ...

Page 10: ...range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to the left of the two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual...

Page 11: ...8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust have been or are wet will result in reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could result in a house fire Do not ...

Page 12: ...on Make sure green light comes on 2 The damper should be completely closed or open no more than 1 4 of the way during start up This will vary depending on your installation and elevation Once fire is established adjust for desired flame increasing the amount the damper is open as the heat setting is increased See Damper Control 3 Adjust feed rate to desired setting by pressing Heat Level Advance b...

Page 13: ...E STOVE Never place your hand near the auger while the stove is in operation We recommend that you not let the hopper drop below 1 4 full TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manua...

Page 14: ...a clean out plate on both sides of the heat exchanger that need to be removed to clean fly ash out of the heat exchanger The cleanouts are located inside the cabinet doors on the lower front corners of the heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash T...

Page 15: ...bottom The creosote should be removed with a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of ...

Page 16: ...PAINTED SURFACES Painted surfaces may be wiped down with a damp cloth If scratches appear or you wish to renew your paint contact your authorized dealer to obtain a can of suitable high temperature paint GLASS We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clean the glass DO NOT use abrasive cleaners...

Page 17: ...ades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For Parts Assistance Call 800 750 2723 Ext 5051 or Email parts usstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items ...

Page 18: ... when possible The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting for extended periods of time If operating the heater on the highest heat setting the room temperature could increase enough and lead to potential ove...

Page 19: ...ctors that attach the gray wires to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not see 8 Control board not sending power to combustion blower If there is no current going to the comb...

Page 20: ...emove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaf...

Page 21: ... secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Remove the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom a...

Page 22: ...nvection blower If there is power being sent to the blower when it is shut off then the control board is fine If there is NOT power being sent to the blower when it shuts off during operation then you have a bad control board Stove Feeds Pellets But Will Not Ignite Possible Causes Possible Remedies Unplug stove first when possible Air damper open too far for ignition Push the air damper in closer ...

Page 23: ... shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hold the top auger biscuit in Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove After you have removed the shaft inspect it...

Page 24: ...rk And Has Black Tips After Stove Has Been On For A While The Burnpot Overfills Possible Causes Possible Remedies Unplug stove first when possible Stove or vent pipe is dirty which restricts airflow through the burnpot Follow all cleaning procedure in the maintenance section of the owner s manual Vent pipe installed improperly Check to make sure the vent pipe has been installed according to the cr...

Page 25: ... 2021 United States Stove Company 25 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6 REPLACEMENT PARTS ...

Page 26: ...8 Auger Motor 1 10 80599 T disc Exhaust 1 11 892187 Auger 1 12 891132 Auger Bushing 1 13 892776 Vented Back Panel 1 14 80709 Convection Blower 1 15 80455 High Limit T disc 1 16 80549 Vacuum Switch 1 17 80602 Exhaust Blower 1 18 88166 Exhaust Blower Gasket 1 19 80462 3 Prong Receptacle 1 20 86633 Ignitor Tube 1 21 80607 Ignitor 1 22 80461 Power Cord 1 23 892764 Gloss Black Side Panels Set of 2 1 89...

Page 27: ... 2021 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM ...

Page 28: ...7 Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No ____...

Page 29: ...icles Remplacé _____________________________ Service de 07 Date _____________________ Nom de l ingénieur ____________________________ N de licence __________________________________ Compagnie ___________________________________ N de téléphone _______________________________ Poêle Inspecté Cheminée balayée Articles Remplacé _____________________________ Service de 02 Date _____________________ Nom ...

Page 30: ...ted States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connectés aux deux broches inférieures de l interrupteur de la trémie comme illustré SCHÉMA DE CÂBLAGE ...

Page 31: ...709 Ventilateur de convection 1 15 80455 T disque haute limite 1 16 80549 Interrupteur à vide 1 17 80602 Ventilateur d échappement 1 18 88166 Joint de soufflante d échappement 1 19 80462 Prise à 3 broches 1 20 86633 Tube allumeur 1 SCHÉMA DES PIÈCES Pour commander des pièces Appelez le 1 800 750 2723 Ext 5051 ou Envoyez un courriel à parts usstove com 21 80607 Allumeur 1 22 80461 Cordon d alimenta...

Page 32: ... 2021 United States Stove Company 25 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6 SCHÉMA DES PIÈCES ...

Page 33: ...e lot de granulés utilisés est peut être de mauvaise qualité Si possible essayez une autre marque de granulés Essayez aussi une marque composée d un autre type de bois résineux plutôt que feuillus Des bois différents présentent des caractéristiques différentes qui affectent la combustion L interrupteur de surchauffe se déclenche tout le temps Causes possibles Solutions possibles Débranchez le poêl...

Page 34: ... l arbre de la tarière et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coincé sur quelque chose Si le moteur ne tourne pas il est défectueux Tarière bloquée Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la ta...

Page 35: ...e tableau de commande n envoie pas de courant à l allumeur Vérifiez la tension qui arrive à l allumeur lors du démarrage Ce doit être la tension nominale Si la tension est inférieure à la valeur nominale vérifiez le câblage Si le câblage est bon c est le tableau qui est défectueux UNE ODEUR DE FUMÉE EST REFOULÉE DANS LA PIÈCE Causes possibles Solutions possibles Débranchez le poêle avant toute cho...

Page 36: ...e Utilisez un testeur de continuité pour tester l interrupteur de sécurité de la trémie remplacer le si nécessaire L arbre de la tarière est coincé Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tarière Soulevez légèrement l arbre de l...

Page 37: ...émie Retirez ensuite le moteur de la tarière en retirant la goupille de la tarière puis retirez les deux boulons qui fixent le support de tarière au tube de tarière Vous pouvez maintenant retirer le support du tube de tarière Retirez les deux boulons du côté du tube de tarière pour déposer le roulement inférieur de la tarière Tirez sur la tarière pour la sortir du tube afin de lever le blocage Le ...

Page 38: ...ir Panne du ventilateur de combustion Lorsque le poêle est en marche vérifiez si le ventilateur de combustion est en fonctionnement Sinon vérifiez l alimentation électrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Si l alimentation est absente reportez vous au point No 8 Le tableau de commande n env...

Page 39: ...onvection surchauffe et déclenche l arrêt de température interne Enlevez la poussière des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit défectueux Le poêle est demeuré sur le réglage le plus élevé pendant de longues périodes En cas d utilisation du poêle sur le réglage de chauffage le plus élevé il se peut que la température de la...

Page 40: ...ropriétaire sont spécifiques à votre appareil Lors de la commande de pièces de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres...

Page 41: ...e l eau pour nettoyer le verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre brisé Le verre de remplacement peut être acheté auprès de votre revendeur américain Stove Si le verre est brisé suivez ces procédures de retrait 1 Retirez les quatre vis et les retenues en verre 2 Tout en portant d...

Page 42: ...e de réparer la totalité du système avant chaque saison de chauffage Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTIS...

Page 43: ...férieurs de l échangeur de chaleur Pour accéder à ces outs propres vous devez retirer les deux panneaux latéraux Les sorties propres sont fixées à la chambre de combustion avec 2 vis 5 16 Retirez les feuilles propres et aspirer les cendres accumulées Cela devrait être fait au moins une fois par mois ou plus fréquemment si de grandes quantités de cendres sont remarqués lors du nettoyage ou si le po...

Page 44: ...pas être modifié Il est contraire à la réglementation fédérale de modifier ce paramètre ou d utiliser ce radiateur à bois d une manière non conforme aux instructions d utilisation de ce manuel AVERTISSEMENT GARDEZ LE COUVERCLE DE LA TRÉMIE FERMÉ À TOUT MOMENT SAUF PENDANT LE REMPLISSAGE NE REMPLISSEZ PAS TROP LA TRÉMIE PROCÉDURE D ARRÊT AVERTISSEMENT NE JAMAIS ARRÊTER CET APPAREIL EN LE DÉBRANCHAN...

Page 45: ...sez la trémie et nettoyez le pot de combustion 1 Appuyez sur l interrupteur ON OFF Assurez vous que le témoin vert s allume 2 Le registre de tirage doit être complètement fermé ou ouvert d un quart au maximum pendant le démarrage C est variable en fonction de votre installation et de l altitude Une fois le feu bien démarré réglez le registre pour obtenir la flamme voulue en l ouvrant au fur et à m...

Page 46: ...ids cendres inférieure à 1 en poids et sel inférieur à 300 parties par million Les granulés mous contenant une quantité excessive de sciure de bois en vrac qui ont été ou sont mouillés réduiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les dégagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela...

Page 47: ...r le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage à deux chiffres des degrés Celsius aux degrés Fahrenheit et vice versa D TOUCHE mode M T Le Mode de fonctionnement du poêle peut être Manuel ou commandé par un Thermostat Des diodes distinctes à gauche de l écran à deux chiffres indiquent le mode de fonctionnement Manuel ou T st...

Page 48: ... installation Un support doit être placé juste au dessous du chapeau de sortie ou à raison d un support tous les 4 pi 1 22 m pour rendre le système plus stable Si vous vivez dans une région où la neige est abondante il est recommandé que la sortie de l installation se trouve à plus de 3 pi 0 91 m pour échapper à la ligne de congère Cette même installation peut être utilisée si le poêle se trouve s...

Page 49: ...éparément INSTALLATION DE L EVACUATION POUR POELE A GRANULES L installation doit comprendre un T de nettoyage pour permettre la collecte des cendres volantes et le nettoyage périodique du système d évacuation des fumées Les coudes à 90 degrés accumulent les cendres volantes et la suie réduisant par là même le débit de l évacuation et les performances du poêle Chaque coude ou T réduit le potentiel ...

Page 50: ...xtérieures doivent être réinstallées et refixées Une prise d air extérieur est obligatoire pour l installation dans une maison mobile Consultez la section Admission d air extérieur et votre concessionnaire pour l achat Vérifiez auprès de votre municipalité si d autres codes sont applicables EXIGENCES POUR L ÉVACUATION AVERTISSEMENT INSTALLEZ L ÉVACUATION DES FUMÉES EN RESPECTANT LES DÉGAGEMENTS SP...

Page 51: ...OTECTEUR DE PLANCHER A B B C À TRAVERS LE MUR INSTALLATION PROTECTEUR DE PLANCHER po mm A Retour à Cuisinière USA 1 26 CAN 8 204 B Côté poêle USA 6 153 CAN 8 204 C De l avant au poêle USA 6 153 CAN 8 458 D Dos et côtés à la cheminée 6 153 DÉGAGEMENTS Votre poêle à granules a été testé et répertorié pour une installation dans une maison résidentielle et mobile conformément aux dégagements indiqués ...

Page 52: ... ADAPTATEUR DE PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON ÉLECTRIQUE SOUS DEVANT OU SUR LE POÊLE NE FAITES PAS COURIR LE CORDON ÉLECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION ...

Page 53: ... comme illustré 2 Déballez les meilleurs contrôles de montage et de veiller à ce que le faisceau de câblage illustré est fixé 3 Connecter les installés en usine faisceaux de câblage sur le panneau de commande comme indiqué 4 Fixez le panneau de commande au dessus du poêle avec deux vis à tôle POUR LE SERVICE À LA CLIENTÈLE APPELER 800 750 2723 EXT 5050 ...

Page 54: ...non date d inspection du système de ventilation existant _________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructions d inst...

Page 55: ... ULC S627 00 Ce manuel décrit l installation et le fonctionnement du chauffe bois Ashley AP5780 Cet appareil de chauffage satisfait aux limites d émissions de bois de berceau de l Agence de protection de l environnement des États Unis de 2020 pour les appareils de chauffage de bois vendus après le 15 mai 2020 Dans des conditions d essai spécifiques ce radiateur a fourni de la chaleur à des taux va...

Page 56: ... restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Conse...

Reviews: