background image

Preparation manual

Gas Fire Front 90-60 PF2

---- Floating Frame --------------- Floating Frame + ----

 

---- Hidden Door --------------------- Hidden Door + ----

 

Serial number:
Production date:

Summary of Contents for 90-60 PF2

Page 1: ...Preparation manual Gas Fire Front 90 60 PF2 Floating Frame Floating Frame Hidden Door Hidden Door Serial number Production date...

Page 2: ...ithout the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document fro...

Page 3: ...nd adjustable legs 24 5 4 Gas Fire Front 90 60 PF2 with Hidden Door 25 5 5 Gas Fire Front 90 60 PF2 with Hidden Door 26 5 6 Gas Fire Front 90 60 PF2 with Hidden Door and adjustable legs 27 5 7 Gas Fir...

Page 4: ...ustrationsare for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety section in detail 3 Make sure that...

Page 5: ...as flue gas channel and the space between the inner pipe and the outer pipe is used as combustion air channel Flue gas channel The flue gases from the appliance flow through the channel to the outlet...

Page 6: ...e gas extraction Bellfires Muelink Grol system Natural draught Poujoulat DUOGAS system Natural draught Ontop Metaloterm US system Natural draught Jeremias STB STB Schoorsteen Techniek Brummen NL H Twi...

Page 7: ...ar the right side of the appliance for an easy connection Only use gas piping of at least and a shut off valve to connect the gas supply to the gas connection of the appliance Make sure that there is...

Page 8: ...of roof and wall outlets Refer to the table hereunder for explanation of the figure Note All the minimum distances in the table are guidelines Consult your national and local regulations for the exact...

Page 9: ...300 P Below balcony 3 or car port roof 2000 Q Beyond the balcony 4 edge 0 R On either side of a balcony 4 1500 S Above ground roof or balcony 4 level 300 T From a surface facing the terminal 500 U Fr...

Page 10: ...the concentric flue The parts that are required for the installation of the concentric flue system are numbered in the illustrations and refer to the part list in 6 Use the universal wall floor suppor...

Page 11: ...the figures 4 28 100 1 10 11 12 13 23 24 17 16 24 18 16 Y Concentric flue connection on appliance 100 150 mm or 130 200 mm Y min max Flue gas restriction plate width Concentric connection on the appl...

Page 12: ...mm Y1 min max X min max Y1 Y2 min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm Concentric connection on the appliance is 130 200 mm 1 0 11 0 m 0 3 0 m 2 0...

Page 13: ...0 150 mm or 130 200 mm Y min max Flue gas restriction plate width Concentric connection on the appli ance is 100 150 mm Concentric connection on the appli ance is 130 200 mm 2 0 4 0 m 30 mm 65 mm 4 0...

Page 14: ...min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm Concentric connection on the appliance is 130 200 mm 1 0 11 0 m 0 3 0 m 2 0 11 0 m 40 mm Caution Make sur...

Page 15: ...lue gas restriction plate width Concentric connection on the appli ance is 100 150 mm Concentric connection on the appli ance is 130 200 mm 2 0 4 0 m 30 mm 65 mm 4 0 12 0 m 40 mm 80 mm Roof outlet usi...

Page 16: ...restriction plate width Concentric connection on the appliance is 100 150 mm Concentric connection on the appliance is 130 200 mm 1 0 11 0 m 0 3 0 m 2 0 11 0 m 40 mm Caution Make sure that Y1 Y2 Y3 i...

Page 17: ...e inner pipe must be positioned above the centre of the outer pipe Rigid concentric flue systems 19 1 10 11 12 13 4 28 100 14 Y 0 16 m X Concentric flue connection on appliance 100 150 mm or 130 200 m...

Page 18: ...6 m X Concentric flue connection on appliance 130 200 mm Y min max X min max Flue gas restriction plate width Concentric connection on the appliance is 130 200 mm 0 5 1 0 m 0 0 6 m 1 0 2 0 m 0 2 6 m R...

Page 19: ...111 113 Concentric flue connection on appliance 130 200 mm Y min max X min max Flue gas restriction plate width Concentric connection on the appliance is 130 200 mm 0 5 1 0 m 0 1 6 m 1 0 3 0 m 0 4 6 m...

Page 20: ...130 200 mm Y1 min max X1 min max Y2 min max X2 min max Flue gas restriction plate width Concentric connection on the appliance is 130 200 mm 0 0 5 m 0 0 5 m 0 5 1 0 m 0 0 6 m 0 5 1 0 m 0 0 5 m 0 0 5 m...

Page 21: ...oncentric flue connection on appliance 130 200 mm Y min max X min max Flue gas restriction plate width Concentric connection on the appliance is 130 200 mm 0 0 5 m 0 0 6 m 0 5 1 0 m 0 3 6 m 1 0 3 0 m...

Page 22: ...5 Technical specification 5 1 Gas Fire Front 90 60 PF2 with Floating Frame Gas connection Technical specification 22 Gas Fire Front 90 60...

Page 23: ...5 2 Gas Fire Front 90 60 PF2 with Floating Frame Gas connection Technical specification Gas Fire Front 90 60 23...

Page 24: ...5 3 Gas Fire Front 90 60 PF2 with Floating Frame and adjustable legs With optional adjustable legs Gas connection Maximum height with adjustable legs Technical specification 24 Gas Fire Front 90 60...

Page 25: ...5 4 Gas Fire Front 90 60 PF2 with Hidden Door Gas connection Technical specification Gas Fire Front 90 60 25...

Page 26: ...5 5 Gas Fire Front 90 60 PF2 with Hidden Door Gas connection Technical specification 26 Gas Fire Front 90 60...

Page 27: ...5 6 Gas Fire Front 90 60 PF2 with Hidden Door and adjustable legs With optional adjustable legs Gas connection Maximum height with adjustable legs Technical specification Gas Fire Front 90 60 27...

Page 28: ...5 7 Gas Fire Front 90 60 PF2 with Hidden Door and convection casing With optional convection case Gas connection Technical specification 28 Gas Fire Front 90 60...

Page 29: ...5 8 Gas Fire Front 90 60 PF2 with Floating Frame and convection casing With optional convection case Technical specification Gas Fire Front 90 60 29...

Page 30: ...e delivered flue restriction plates in mm Concentric flue connection 100 150 Concentric flue connection 130 200 Roof mounted outlet Horizontal wall outlet 30 mm 40 mm 40 mm 50 mm 50 mm 65 mm 65 mm 80...

Page 31: ...listedin this chapter The guarantee on the appliance lapses if it is installed fully or partially with other components or a different flue system The concentric flue 100 mm 150 mm and 130 mm 200 mm...

Page 32: ...anced flue pipe L 1000 mm BLACK 12 302291 Telescopic twin wall balanced flue pipe L min 325 max 440 mm 346511 Telescopic twin wall balanced flue pipe L min 965 max 1750 mm 13 302292 Adjustable length...

Page 33: ...46239 Twin wall balanced flue elbow 90 segment BLACK 15 302298 Twin wall balanced flue elbow 45 ribbed 346240 Twin wall balanced flue elbow 45 segment BLACK 329514 Twin wall balanced flue elbow 30 rib...

Page 34: ...ll termi nation kit L 600 mm adjustable including a set of wall spacer plates ANTHRACITE 346241 Horizontal wall termi nation kit L 600 mm adjustable including a set of wall spacer plates Stainless ste...

Page 35: ...ex appliance 100 mm flex and 100 mm rigid 100 mm flex 27 302279 Stainless steel adapter piece 150 fire to flexi ble 148 mm external rigid x 148 mm in ternal flex appliance 150 mm flex 28 302217 Stainl...

Page 36: ...ith gauging orifice L 165 mm 35 302303 90 concentric bend with inspection panel 36 321948 Universal wall floor support 150 mm Color Stainless steel polished antr Anthracite or Black color lacquer matt...

Page 37: ...used to extractthe flue gasses The temperature classification of the flexible pipe must be at least T450 Available components for the concentric flue system natural draught Gas Fire Front 90 60 37...

Page 38: ...02308 Twin wall balanced flue pipe L 500 mm 111 302309 Twin wall balanced flue pipe L 1000 mm 112 346509 Telescopic twin wall balanced flue pipe L min 325 max 440 mm 346512 Telescopic twin wall balanc...

Page 39: ...b bed 346508 Twin wall balanced flue elbow 15 segment 119 302313 Horizontal wall termination kit L 600 mm adjusta ble including a set of wall spacer plates ANTHRA CITE 343950 Horizontal wall terminati...

Page 40: ...flex ap pliance 130 mm flex and 130 mm rigid 130 mm flex 127 302282 Stainless steel adapter piece 200 appliance to flexible 198 mm external rigid x 198 mm internal flex appliance 200 mm flex 128 3022...

Page 41: ...Black color lacquer matt Adjustable roof flashing for a slope 45 can be supplied on request When installing a balanced flue closed gas appliance in an existing chimney ensure stainlesssteel flexible l...

Page 42: ...5 Twin wall balanced flue pipe L 950 mm 12 34100429 Telescopic twin wall balanced flue pipe L min 390 max 640 mm 14 34100441 Twin wall balanced flue elbow 90 15 34100421 Twin wall balanced flue elbow...

Page 43: ...2 Roof flashing suitable for a brick roof with a roof pitch of 30 45 17 45150173 Roof flashing suitable for a tiled roof with a roof pitch of 30 45 18 45150169 Roof flashing for existing chimney or fl...

Page 44: ...ng plates Fire stops suitable for a roof pitch of 40 50 34 34100407 Concentric pipe with inspection opening L 250 mm 36 45150165 Roof support universal 150 mm 36 45150081 Floor support universal 150 m...

Page 45: ...Twin wall balanced flue pipe L 950 mm 112 34130429 Telescopic twin wall balanced flue pipe L min 390 max 640 mm 114 34130441 Twin wall balanced flue elbow 90 115 34130421 Twin wall balanced flue elbo...

Page 46: ...inishing plates Fire stops suitable for a roof pitch of 10 30 37130427 Set of ceiling finishing plates Fire stops suitable for a roof pitch of 30 40 37130428 Set of ceiling finishing plates Fire stops...

Page 47: ...10 US 50 10 Twin wall balanced flue pipe L 500 mm 11 US 100 10 Twin wall balanced flue pipe L 1000 mm 12 USPP 10 Telescopic twin wall balanced flue pipe L min 60 max 250 mm 14 USB 90 10 Twin wall bala...

Page 48: ...pitch 20 45 with lead flashing 17 USDH 10 Roof flashing plate for roof pitch 5 30 18 USDP 10 Roof flashing for existing chimney or flat roof 18 USDPAL 10 Roof flashing Aluminum For existing chimney or...

Page 49: ...3 USEB 10 Fitting bracket 24 USCP 10 Set of ceiling finishing plates Fire stops Centering plates 24 USDQ 10 Roof support 25 USSAN 10 Renovation set 25 USSAN1 10 Top of renovation set 25 USSAN2 10 Bott...

Page 50: ...oncentric pipe with gauging orifice L 150 mm 35 USBI 10 90 concentric bend with inspection panel USR 10 Rosette smooth 150 mm USMPG 10 Wall plate large 150 mm square 300 mm USAH 10 Spacer bracket USVG...

Page 51: ...US 50 13 Twin wall balanced flue pipe L 500 mm 111 US 100 13 Twin wall balanced flue pipe L 1000 mm 112 USPP 13 Telescopic twin wall balanced flue pipe L min 60 max 250 mm 114 USB 90 13 Twin wall bal...

Page 52: ...itch 20 45 with lead flashing 117 USDH 13 Roof flashing plate for roof pitch 5 30 118 USDP 13 Roof flashing for existing chimney or flat roof 118 USDPAL 13 Roof flashing Aluminum For existing chimney...

Page 53: ...USEB 13 Fitting bracket 124 USCP 13 Set of ceiling finishing plates Fire stops Centering plates 124 USDQ 13 Roof support 125 USSAN 13 Renovation set 125 USSAN1 13 Top of renovation set 125 USSAN1 13...

Page 54: ...h inspection panel L 250 mm 134 USEM 13 Concentric pipe with gauging orifice L 150 mm 135 USBI 13 90 concentric bend with inspection panel USR 13 Rosette smooth 200 mm USMPG 13 Wall plate large 200 mm...

Page 55: ...o Ontop Art Order No Description USAH 13 Spacer bracket USVG 13 10 Concentric reduction of 130 200 mm 100 150 mm Available components for the concentric flue system natural draught Gas Fire Front 90 6...

Page 56: ...ll balanced flue pipe L 250 mm 12 H TWIN 742100 150 Telescopic twin wall balanced flue pipe L min 1100 max 1400 mm 12 H TWIN 467100 150 Telescopic twin wall balanced flue pipe L min 1100 max 1900 mm 1...

Page 57: ...flue elbow 45 14 ATWIN 60100 150 Twin wall balanced flue elbow 90 14 ATWIN 60F100 150 Twin wall balanced flue elbow 90 Short Especially for connection to a wall termination 16 A 463100 150 Roof termin...

Page 58: ...ith lead flashing and storm collar 17 ATWIN 60DD 100 150 Roof flashing for roof pitch 45 with lead flashing and storm collar ATWIN 307 100 150 Storm collar 24 ADBL DW100 150 Set of ceiling finishing p...

Page 59: ...cap and condensation opening ATWIN 465 100 150 Adapter H TWIN 100 150 Flex Stainless steel 100 mm Incl Ceiling plate 300x300 mm ATWIN 466100 150 Adapter Flex Stainless steel 100 mm H TWIN 100 150 Incl...

Page 60: ...l balanced flue pipe L 250 mm 112 H TWIN 742130 200 Telescopic twin wall balanced flue pipe L min 1100 max 1400 mm 112 H TWIN 467130 200 Telescopic twin wall balanced flue pipe L min 1100 max 1900 mm...

Page 61: ...tion to a wall termination 124 ADBL DW130 200 Set of ceiling finishing plates Fire stops 120 ATWIN 45130 200 Locking band Screw fastening Standard on all com ponents 123 ATWIN 22130 200 Wall strap adj...

Page 62: ...130 200 Flex Stainless steel 130 mm Incl Ceiling plate 300x300 mm ATWIN 466130 200 Adapter Flex Stainless steel 130 mm H TWIN 130 200 Incl Chimney ceiling plate 300x300 mm 136 ASDH2 130 200 Universal...

Page 63: ...00 150 Twin wall balanced flue pipe L 1000 mmIncluding locking band 10 TWG14100 150 Twin wall balanced flue pipe L 500 mmIncluding locking band 10 TWG15100 150 Twin wall balanced flue pipe L 250 mmInc...

Page 64: ...18100 150 Twin wall balanced flue elbow 45 Including locking band 14 TWG60100 150 Twin wall balanced flue elbow 90 Including locking band 14 TWG178610 0 150 Twin wall balanced flue elbow 90 with suppo...

Page 65: ...W38 150 Roof flashing with a roof pitch of 26 35 with flex alu flashing and storm collar 17 TW54 150 Roof flashing with a roof pitch of 36 45 with flex alu flashing and storm collar 18 TW52150 Roof fl...

Page 66: ...for the wall strap ZUWA704L 200 mm ZU WA891250 Extension pieces for the wall strap ZUWA704L 250 mm ZUWA706 Extension pieces for the wall strap ZUWA704L 400 mm WA 50 360 mm 24 ZU DA074150 Set of ceilin...

Page 67: ...chaft DE 25 TWG173210 0 150 Chimney flat roof ceiling platewith adapter 100 rig id flex to TWIN GAS 33 TWG317100 150 Concentric T piece 90 Including locking band 34 TWG51100 150 Concentric pipe with g...

Page 68: ...rt with transverse supportType III 750 mm Distance to wall WA 150 250 mm DW407 Wall support with transverse supportType IV 1030 mm Distance to wall WA 250 360 mm 17 24 LUX ECO150 Insulation roof flash...

Page 69: ...0 200 Twin wall balanced flue pipe L 1000 mmIncluding locking band 110 TWG14130 200 Twin wall balanced flue pipe L 500 mmIncluding locking band 110 TWG15130 200 Twin wall balanced flue pipe L 250 mmIn...

Page 70: ...18130 200 Twin wall balanced flue elbow 45 Including locking band 114 TWG60130 200 Twin wall balanced flue elbow 90 Including locking band 114 TWG178613 0 200 Twin wall balanced flue elbow 90 with sup...

Page 71: ...W38 200 Roof flashing with a roof pitch of 26 35 with flex alu flashing and storm collar 117 TW54 200 Roof flashing with a roof pitch of 36 45 with flex alu flashing and storm collar 118 TW52200 Roof...

Page 72: ...for the wall strap ZUWA704L 200 mm ZU WA891250 Extension pieces for the wall strap ZUWA704L 250 mm ZUWA706 Extension pieces for the wall strap ZUWA704L 400 mm WA 50 360 mm 124 ZU DA074200 Set of ceili...

Page 73: ...haft DE 125 TWG173213 0 200 Chimney flat roof ceiling platewith adapter 100 rig id flex to TWIN GAS 133 TWG317130 200 Concentric T piece 90 Including locking band 134 TWG51130 200 Concentric pipe with...

Page 74: ...mm Distance to wall WA 150 250 mm DW407 Wall support with transverse supportType IV 1030 mm Distance to wall WA 250 360 mm 100 TWGR Concentric reduction Jeremias TWIN GAS 130 200 Jeremias TWIN GAS 10...

Page 75: ...nox PLA 100 153 mm L 230 mm INOX BLACK 10 2PLAELDR100250 Twin wall bal anced flue pipe L 250 mm INOX 2PLAELDR100250NO Twin wall bal anced flue pipe L 250 mm INOX BLACK 10 2PLAELDR100330 Twin wall bal...

Page 76: ...0NO Telescopic twin wall bal anced flue pipe L min 300 max 500 mm IN OX BLACK 14 2PLACO90100 Twin wall bal anced flue el bow 90 IN OX 2PLACO90100NO Twin wall bal anced flue el bow 90 IN OX BLACK 15 2P...

Page 77: ...DIVS5IN150 Roof flashing for a roof pitch of 5 30 IN OX 2DIVS5IN150NO Roof flashing for a roof pitch of 5 30 IN OX BLACK 17 2DIVS3IN150 Roof flashing for a roof pitch of 31 45 INOX 2DIVS3IN150NO Roof...

Page 78: ...or a roof pitch of 31 45 with INOX cone 2DIVS3PR160 Roof flashing large tile mod el lead 1 0mm thick for a roof pitch of 31 45 with INOX cone 17 2DIVC5LA153NO Cone cover for roof flash ing lead for a...

Page 79: ...BLACK 20 2PLACOJO100 Locking band quick fasten ing INOX 2PLACOJO100NO Locking band quick fasten ing INOX BLACK 21 2PLAJOIF100 Fiber seal 23 2PLACOMU100 Wall strap IN OX 2PLACOMU100NO Wall strap IN OX...

Page 80: ...ette with 4 mounting holes INOX BLACK 2PLAROSA100BL Rosette with 4 mounting holes INOX WHITE 34 2PLAEMES100 Concentric pipe with gauging ori fice L 250 mm INOX 2PLAEMES100NO Concentric pipe with gaugi...

Page 81: ...00mm INOX 2PLAADA71002020NO Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x200mm INOX BLACK 25 2PLAADA71002525 Adapter Modi nox PLA Flexible pipe with chimney bottom finis...

Page 82: ...71002040 Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x400mm INOX 2PLAADA71002040NO Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x400mm INOX...

Page 83: ...hing plate 250x250mm INOX 2PLAADA61003030 Adapter Flexi ble pipe Modinox PLA with chimney top finishing plate 300x300mm INOX 2PLAADA61002040 Adapter Flexi ble pipe Modinox PLA with chimney top finishi...

Page 84: ...ation kit FOURP for ceiling pas sage Com plete wood floor kit 2PTGKIFO100BE Insulation kit FOURP for ceiling pas sage Com plete concrete floor kit 2PTGKIFOV100 Insulation kit FOURP for ceiling stor ey...

Page 85: ...ELNO Bellfires appli ance connec tion Adapter Bellfires 130 200 mm Modinox PLA 130 200 mm L 230 mm INOX BLACK 100 2PLAMAFM130100BEL Bellfires appli ance connec tion Adapter Bellfires 130 200 mm Modino...

Page 86: ...0250NO Twin wall bal anced flue pipe L 250 mm INOX BLACK 110 2PLAELDR130330 Twin wall bal anced flue pipe L 330 mm INOX 2PLAELDR130330NO Twin wall bal anced flue pipe L 330 mm INOX BLACK 110 2PLAELDR1...

Page 87: ...90 IN OX 2PLACO90130NO Twin wall bal anced flue el bow 90 IN OX BLACK 115 2PLACO45130 Twin wall bal anced flue el bow 45 IN OX 2PLACO45130NO Twin wall bal anced flue el bow 45 IN OX BLACK 115 2PLACO30...

Page 88: ...VS5IN200NO Roof flashing for a roof pitch of 5 30 INOX BLACK 117 2DIVS3IN200 Roof flashing for a roof pitch of 31 45 INOX 2DIVS3IN200NO Roof flashing for a roof pitch of 31 45 INOX BLACK 117 2DIVRTS1...

Page 89: ...or a roof pitch of 31 45 with IN OX cone 2DIVS3PR210 Roof flashing large tile mod el lead 1 0mm thick for a roof pitch of 31 45 with IN OX cone 117 2DIVC5LA200NO Cone cover for roof flash ing lead for...

Page 90: ...LACK 120 2PLACOJO130 Locking band quick fasten ing INOX 2PLACOJO130NO Locking band quick fasten ing INOX BLACK 121 2PLAJOIF130 Fiber seal 123 2PLACOMU130 Wall strap IN OX 2PLACOMU130NO Wall strap IN O...

Page 91: ...ette with 4 mounting holes INOX BLACK 2PLAROSA130BL Rosette with 4 mounting holes INOX WHITE 134 2PLAEMES130 Concentric pipe with gauging ori fice L 250 mm INOX 2PLAEMES130NO Concentric pipe with gaug...

Page 92: ...200mm INOX 2PLAADA71302020NO Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x200mm INOX BLACK 125 2PLAADA71302525 Adapter Modi nox PLA Flexible pipe with chimney bottom fin...

Page 93: ...A71302040 Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x400mm INOX 2PLAADA71302040NO Adapter Modi nox PLA Flexible pipe with chimney bottom finish ing plate 200x400mm INO...

Page 94: ...shing plate 250x250mm INOX 2PLAADA61303030 Adapter Flexi ble pipe Modinox PLA with chimney top finishing plate 300x300mm INOX 2PLAADA61302040 Adapter Flexi ble pipe Modinox PLA with chimney top finish...

Page 95: ...ation kit FOURP for ceiling pas sage Com plete wood floor kit 2PTGKIFO130BE Insulation kit FOURP for ceiling pas sage Com plete concrete floor kit 2PTGKIFOV130 Insulation kit FOURP for ceiling stor ey...

Page 96: ...Your Barbas dealer 002 21 07 2022 352518 252 002...

Reviews: