292 1037 000  ·  1087

  

Operating and Installation 

Instructions 
for

 

Wood Burning Stoves

EN

ORANIER

Rota Tre I

Summary of Contents for Rota Tre I

Page 1: ...292 1037 000 1087 Operating and Installation Instructions for Wood Burning Stoves EN ORANIER Rota Tre I...

Page 2: ...2 Design 6 3 Flue tube connection and setup of the wood burning stove 6 3 1 Connection of the flue tube 6 3 2 Setup of the wood burning stove 7 4 Technical data 8 5 Operating the wood burning stove 9...

Page 3: ...est To enable our customer service team to organise repairs and provide the necessary spare parts with complete care and precision we will need the fol lowing information 1 Your full address 2 Your te...

Page 4: ...Keep the oper ating instructions in a safe place so that you can remind yourself of the correct operating procedures when starting a new period of heating Type tested in accordance with EN 13240 Secti...

Page 5: ...tion air supply If necessary the wood burning stove can be equipped with a connection for an ex ternal combustion air supply See Fig 1 For especially well insulated rooms an air supply from outside ca...

Page 6: ...checked by a specialist 3 Flue tube connection and setup of the wood burning stove 3 1 Connection of the flue tube Your wood burning stove can optionally be connected upwards or to the rear To connect...

Page 7: ...system for the first time please remove all documents and accessory parts from the firebox and ash box Remove all stickers so there is no residue from the view ing pane Fig 2 Caution Ensure before set...

Page 8: ...fficiency wood BB7 80 2 80 8 CO 985 504 mg m3 NOx 76 132 mg m3 CnHm 56 66 mg m3 Dust 33 31 mg m3 For Austria For efficiency and emissions values see CE mark Exhaust mass flow 4 5 g s Feed pressure for...

Page 9: ...ng of the firebox door and the re moval of the trivet to empty the ashes should always be carried out using the tool provided Failure to do so risks injury and burns Heating mode is only permitted whe...

Page 10: ...d you wish to add more fuel We recommend keeping the secondary air controller open as much as possible so that as much pane flush air as possible can prevent soot particles from depositing on the view...

Page 11: ...new air When outdoor temperatures are above 16 C malfunctions can occur due to a lack of chim ney draught feed pressure In this case use less fuel and open the pri mary air controller wider 5 7 Maximu...

Page 12: ...mney fire If an unsuitable fuel or a fuel that is too wet is used deposits in the chimney can ignite causing a chimney fire A chimney or stove fire can occur if soot de posits in the chimney caused by...

Page 13: ...The repair will generally be carried out at the setup location or under exceptional circumstances at our customer service workshop Ap pliances due for repair must be made accessible so that no damage...

Page 14: ...faisant Freisetzung von gef hrlichen Stoffen D gagement de substances dangereuses NPD Max Wasserbetriebsdruck Pression maximale de l eau Abgastemperatur bei Nennw rmeleistung Temp rature des fum es la...

Page 15: ...ed body La conformit de l appareil de chauffage utilisant du combustible solide avec les exigences de la norme a t contr l e aupr s de l organisme de contr le agr Name der anerkannten Pr fstelle Name...

Page 16: ...ir Gr s sable Schwarz Keramik seidenwei Black Ceramic white silk 4794 87 A03 Noir C ramique blanc soyeux Stahl schwarz Abdeckung Kalkstein bianco Black steel Cover Limestone bianco 4794 89 A03 Acier n...