Save These Instructions

Installation and Operating Manual

Magnafire Series Coal Stoves - Mark I, II, and III

SAFETY NOTICE

PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL OR USE YOUR NEW ROOM HEATER. FAILURE 

TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

APPROVED FOR USE IN THE U.S. AND CANADA

IF THIS HARMAN STOVE IS NOT INSTALLED CORRECTLY, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, 

FOLLOW INSTALLATION DIRECTIONS PRECISELY.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSPECTION REQUIREMENTS 

FOR YOUR AREA.

CONTACT YOUR LOCAL AUTHORITY (SUCH AS THE MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, 

FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.

CETTE GUIDE D’UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN 

HOME HEATING. 

R3

#3-90-70746

Summary of Contents for MARK I

Page 1: ...E U S AND CANADA IF THIS HARMAN STOVE IS NOT INSTALLED CORRECTLY A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS PRECISELY CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC...

Page 2: ...re a first time coal burner keep in mind that you will not have instant success with maintaining a fire No one does Following these instructions should help you with the basic principals Safety Notice...

Page 3: ...2 2 Locating The Stove 2 3 Assembly 2 4 General Information 3 Venting 3 1 Types of Chimneys 3 2 Common Chimney Problems 3 3 What To Do If You Have A Problem 3 4 Chimney Details 4 Grates 4 1 Grate Syst...

Page 4: ...quire ments you must follow local codes 1 3 CURING PAINT During the first few hours of burning a blue smoke will be observed rising from the painted surfaces of the stove This is the paint being cured...

Page 5: ...ned installer Preferably one who is certified by the National Fire place Institute or similar certification agency B Before starting Installation check for proper clear ance to combustibles where the...

Page 6: ...on building inspector fire department personnel etc If a listed and certified manufactured chimney is to be used make certain it is installed in accordance with the manufacturers instructions and all...

Page 7: ...not enough oxygen getting to the fire E Remember open the draft control and crack the door open slightly before reloading or checking the fire F Check the ashes The ash pan and firebox may be overload...

Page 8: ...ld be bright and vigor ous If the fire is burning hot and there is a deep bed of hot coals full loads of coal can be added at any time However if there is not a deep bed of coals it is best to add in...

Page 9: ...lean the fan If there are pets in your house you may want to check this more frequently Grates Keep ash pan emptied Twice a day Chimney and connector Avoid chimney fires On a regular schedule check fo...

Page 10: ...Magnafire Series Coal Stoves 10 Optional Water Coil 7 Optional Hot Water Coil Plumbing Diagrams Inside Nut Stove Body Packing Outside Nut Washer...

Page 11: ...han the top leg of the coil The tank should be elevated if necessary to allow for proper thermo siphon action the method by which water will circulate automatically through the system Circulating Pump...

Page 12: ......

Page 13: ......

Page 14: ...Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 15: ...Service Maintenance Log Date Of Service Performed By Description Of Service...