9

Body

Power switch

[ー] Power ON  [◎] Power OFF

Exhaust  vent  of 

the sample

This is an exhaust vent of the sample. It is possible to connect a tube 

with an outer diameter of 6mm (* Tefl on tube is recommended).

Suction nozzle 

attaching

This is inlet of attachment suction nozzle. This suction nozzle can be 

connected to a tube with an inner diameter of 4 mm. ( ※ Tefl on tube 

is recommended)

Button

NEXT Button:

This is used to move to the next item / value in the 

MENU screen.

MENU/ENTER Button:

This makes moving to the MENU screen. It 

is used as an enter button in the MENU screen. Peak value can be 

displayed by 2 seconds press of this button.

BACK Button:

This is used to return back to the previous item / value 

in the MENU screen.

Serial number

This is the unique serial number of this product. You may be asked for 

this number when making an inquiry. So please have it ready when 

you contact us.

microSD card slot

This is a microSD card slot. Please insert the SD card deeply and fi rmly. 

Although  measurement  is  possible  without  the  SD  card,  the  data 

collection function cannot be used.

Only 2GB or less capacity of microSD card can be used. If the capacity 

is more than that, it may cause a reading error or a malfunction.

L i t h i u m   c o i n 

battery (CR2032) 

slot

This is Lithium coin battery (CR2032) slot. Please insert it deeply and 

fi rmly.

AC adapter socket

This is a socket for AC adapter. When using the AC adapter, please be 

sure to use the included adapter.

Cell batteries box

Four alkaline dry cell batteries (AA) are inserted in here. By using dry 

cell batteries, measurement is possible without the AC power.

Strap

This is a hole to attach the included strap. Please use the strap to 

prevent falling. Other straps that is commercially available can also be 

attached.

( 4 0 0 ): D a t e 

c o u n t - d o w n 

during using Date 

collect mode

This is displayed during data collection. It does count-down to start 

writing data into the internal recording fi le. When it becomes 0, it starts 

writing.Although  the  measurement  is  continued  during  writing,  the 

operation will become temporarily slow. So please be careful not to miss 

the measurement value, for example, by interrupting the measurement 

when it approaches 0.

Peak value

This is displayed only during peak measurement mode. Display / cancel 
can be selected from the MENU or holding MENU button for 2 seconds.

Date and Time

This shows the current date and time. If the date and time are not 

correct, you can adjust it from the calendar function of MENU.

Simple

temperature  and 

humidity display

This  is  displayed  only  during  temperature  and  humidity  mode.  T: 
Temperature, H: Humidity

Summary of Contents for Kagurobo Polfa

Page 1: ...ODORSENSOR MANUAL Ver 1 1...

Page 2: ...the odor sensor KAGUROBO POLFA In order to use this equipment safely and correctly please read this manual carefully before starting using it And please keep this document not to be damaged or lost so...

Page 3: ...the Power 13 6 2 Idling Operation 13 6 3 Con rming the Settings 14 6 4 Reading the Measured Value 14 6 5 Finishing Measurement 15 7 MENU Screen Function Setting 7 1 MENU 16 7 2 D COLLECT 16 7 3 PEAK H...

Page 4: ...this Do NOT disassemble or modify Do not disassemble or modify the product There is a risk of re electric shock user s injury or the product malfunction Not explosion proof Do not use the product in...

Page 5: ...ozone over 100 ppm for 2 hours Please note that it may cause product malfunction or a ect the life and characteristics of the sensor by usage installation or storage in the following places and envir...

Page 6: ...oduct rstly please check the product and included items for any problems or abnormalities before using If you nd any damage or defects please contact the retailer you bought In addition if there is a...

Page 7: ...value during measurement on the screen This function is useful to avoid missing the measurement values Data collection function Measurement data can be recorded by using the data collection function...

Page 8: ...g mark Remaining cell batteries mark Real time graph Mmeasurement odor values Peak value Current date and time Temperature and humidity Button Name of Each Part Maintenance or Using Zero adjustment mo...

Page 9: ...4 AC DC12V 1A 0 40 10 50 MADE IN JAPAN Power switch Serial number Strap hole Cell batteries box microSD slot Lithium coin battery CR2032 slot AC adapter socket Power switch Vent hole of temperature a...

Page 10: ...g data collection Scale mode mark Lights up only during scale mode MicroSD card inserting mark Lights up During microSD card recognition Blink During writing data into microSD card If it continues bli...

Page 11: ...n L i t h i u m c o i n battery CR2032 slot This is Lithium coin battery CR2032 slot Please insert it deeply and rmly AC adapter socket This is a socket for AC adapter When using the AC adapter please...

Page 12: ...ter measurement frequent sensor cleaning idling operation under clean air can prevent deterioration of the sensor After measuring the odor including follows please turn o the power after idling until...

Page 13: ...perature and humidity Prohibition of liquid oil powder and dust suction The measured value of this product is a ected and uctuated by the gas or the temperature humidity of the measurement environment...

Page 14: ...eci ed position Please prepare dry cell batteries or AC adapter Please install dry cell batteries alkaline AA or connect AC adapter according to the measurement location and usage conditions Please no...

Page 15: ...n the right When this value becomes less than 300 under clean air environment idling is completed Under clean air environment means outdoors where the air is clean or the air that has ltered through t...

Page 16: ...LE Scale function ON OFF Reading the Measured Value Please execute measurement with the suction port suction nozzle closing to the object Depending on the odor the value may peak immediately or may ri...

Page 17: ...0 or less Turning the power o while the sensor is contaminated may accelerate the deterioration of the sensor In the case of the measured value exceeding 2 000 the measurement is not recommended since...

Page 18: ...d but it will be forcibly stopped when the cumulative use time reaches 4 500 hours from the point of durability of the pump Also please note that the maximum continuous recording time varies depending...

Page 19: ...s not turn o During writing blinks and the operability is a little slow temporarily Therefore please check carefully the counter of countdown 400 If the SD card is not inserted in this case is not dis...

Page 20: ...ct and it is not aimed the function as an observation equipment In order to prevent misunderstanding the unit is not displayed with the temperature humidity value The displayed temperature and humidit...

Page 21: ...becomes faster By selecting YES it returns to the measurement screen a n d t h e v e r t i c a l a x i s i s changed To change back the setting please retry from the beginning Erasing all the data in...

Page 22: ...to make it easy to recognize the fluctuation that is small measured values and di cult to read such when the odor is weak to be re ected in the measured values or to detect odorous substances such as...

Page 23: ...shing and button is displayed on the screen and then 120 second countdown is started The operation after 120 seconds will be one of following 3 patterns depending on the degree of deterioration of the...

Page 24: ...4 41 43 324 28 50 14 41 44 323 28 50 14 41 44 324 28 50 14 41 45 324 28 50 The following information is stored in the csv le File Name Hour Min Sec at the measurement started Scale 1 to 5 Date YYYY MM...

Page 25: ...uch as alcohol or thinner etc Storage Storing the product with removing dry cell batteries Leaving the batteries in the product may cause liquid leakage of battery that cause product malfunction Do no...

Page 26: ...in zero adjustment mode The suctioned air is dirty or the sensor is severely degraded Please try to replace the activated carbon cartridge to recover If still not recover maintenance is required E001...

Page 27: ...ime exceeds 4 500 the product will stop the function for safety reasons Also we o er repair or replacement of failure product or sensor etc in all time All of above services will be performed at KARUM...

Page 28: ...alcohol is widely used in cosmetics and stationeries Because POLFA sensitively reacts these substances the measured values may unexpectedly be high in case of these substances In this case please try...

Page 29: ...ing scale mode 0 max9 999 Power Alkaline dry cell AA x 4 or AC adapter AC adapter AC100 240V DC12V 1A Power consumption When using alkaline dry cell Backlight lighting 0 9W When using AC adapter Backl...

Page 30: ...28 MEMO...

Page 31: ...29 MEMO...

Page 32: ......

Reviews: