6 Inspection and maintenance – 6.1 Daily inspection
157
Hook attachment
1. Lock mechanism
2. Sensor alignment
3. Alignment pin
4. Lift hook
5. Lock guide, lock lugs
•
Check that the lock lugs are working by moving in towards
double containers until the "Alignment" light illuminates. The
display for the control and monitoring system, see Overview
Spirit Delta, page 44 (position 51), shows by means of sym-
bols which ones are aligned. Check that the alignment pins
have contact against the containers.
•
Check that twistlock/lock lugs open/lock works. This is done
by pressing in the override button (not for lock lugs) and check
that green light is on at locked twistlock/lock lugs and red light
is on at open twistlock/lock lugs.
•
Check that the override button works. This is done by press-
ing in the override button and checking that warning lamp for
by-pass of hydraulic functions (position 35) is on.
8.
Check the machine’s operating hours – notify the foreman/super-
visor if the machine is close to a service interval.
9.
Notify the foreman/supervisor immediately if any defects are de-
tected on the machine.
10. In cold weather:
•
check that wiper blades have not frozen to the windscreen
•
remove snow from air inlets and radiator grill
•
antifreeze in washer fluid
•
connect auxiliary heater for cab and engine
Electrical box for auxiliary heater is located by the cab steps
on the left side of the machine.
11. Check if any error codes are active.
See the section
5.3 Error codes
.
0
0
8
1
4
0
1
2
5
3
4
WARNING
Do not use the machine if the system for locking con-
tainers does not work.
Extreme hazard to personal health and risk of proper-
ty damage!
Use of the machine must be discontinued, and it has
to be taken to a service workshop for needed actions.
Summary of Contents for DCF100-45E7
Page 2: ......
Page 4: ......
Page 9: ...8 1 Foreword 1 3 Inspection and maintenance...
Page 82: ...218 8 Environment and standards...
Page 87: ......