• DRY CONTACT “
C3-C3
C3-C3
“
CONFIGURATION
IMPORTANT!:
The function is available by
connecting the dry contact C3-C3 on the power
board and is active only if JUMPER MC4 is open.
The dry input contact (NC
*
) C3-C3 enables two
types of operation that can be activated from the
KVX RHQ remote control:
• Fireplace “
FirE
” function (default)
• Boiler “
bOIL
” function
From the main menu, access the “
SEt
” menu and
use the
TOUCH PAD
to display the “
C3C3
” menu.
Press the “
Enter
” key to confirm.
Use the
TOUCH PAD
to choose either the
FirE
or
bOIL
function.
Confirm the selected function with the “
Enter
” key.
• DRY CONTACT “
fC-FC
fC-FC
“
CONFIGURATION
IMPORTANT!:
The function is available by
connecting contact FC-FC on the power board.
Contact FC-FC (230V output) enables two types of
operation that can be activated by means of the
KVX RHQ remote control:
• “
ALrN
” function (default)
Remote alarm status signal
• “
ConS
” function 230V enabling signal for
synchronisation with external units.
From the main menu, access the "
SEt
” menu and
use the
TOUCH PAD
to display the “
FrSt
” menu.
Press “
Enter
” to confirm.
Use the
TOUCH PAD
to choose either the
AlrN
or
ConS
function.
Confirm the selected function with the “
Enter
” key.
NO*= normally open contact
NC*= normally closed contact
Summary of Contents for KVX-150 RHQ
Page 2: ......
Page 3: ...INSTRUKCJAOBS UGI OWNER SMANUAL BEDIENUNGSANLEITUNG 5 65 123 PL EN DE...
Page 4: ......
Page 33: ...33 Polski 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Instalacja sterownika na cianie...
Page 63: ...63 Polski...
Page 64: ......
Page 91: ...91 English 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Installing controller on the wall...
Page 121: ...121 English...
Page 122: ......
Page 149: ...149 Deutsch 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Installation der Wandbedieneinheit...
Page 179: ...179 Deutsch...
Page 180: ...kaisai com...