92
English
DAY
°C
KVX RHQ REMOTE CONTROL
• INTRODUCTION
This unit was designed for the remote control of con-
trolled mechanical ventilation units.
The control panel features a Main Screen
that offers access to two setting submenus:
1.
USER
Settings Menu where the
user can select the operating mode and set
the clock;
2.
TECHNICAL
Settings Menu where the installer
can calibrate the flow rate, change the standard
unit operating parameters, set functions and
monitor the operating state.
On the main screen, the user can view alarm
reports and readings of the environmental tem-
perature and humidity.
The
USER Settings Menu offers these options:
1. Manual selection of preset ventilation speed:
a)
Party Mode
- Intensive timed ventilation
b)
Holiday Mode
- Permanent or customised An-
ti-mould ventilation
2. Activation/deactivation of
Automatic Mode
.
An icon indicates activation of “
Automatic
Mode
”.
3. Customised selection of desired air flow rate
in manual mode:
a) 100% - Nominal ventilation (standard)
b) 70% - Reduced ventilation (nighttime)
c) 45% - Humidity Control for High Humidity Rate
Environments
d) 25% - Humidity Control for Low Humidity Rate
Environments
4. Voluntary activation of free-cooling mode.
5. Weekly Programming
The MAIN SCREEN features the following op-
tions:
1. Indication of the activation of the Weekly Pro-
gram
4
.
2. The preheating icon indicates activation of
Antifreeze Mode.
3. A timed warning icon is activated to suggest
replacing the filters.
4. A bypass icon indicates the activation of the
free-cooling mode.
4
The 4 Weekly Programs can be set by the installer and an
-
other 4 weekly programs can be set up according to the user’s
specific requirements.
The User Settings menu allows the user to enable or disable
the Weekly Program configured by the installer.
The TECHNICAL Menu offers these options:
1. Possibility of confirming or editing the oper-
ating parameters and functions.
2. Monitoring of work conditions.
3. Set the fan calibration design flow rates.
4. Input and Selection of the Weekly Program
available to the user.
5. Configuration of dry contacts, relays and Mod-
bus parameters
Indoor Air
Temperature
Display
Summary of Contents for KVX-150 RHQ
Page 2: ......
Page 3: ...INSTRUKCJAOBS UGI OWNER SMANUAL BEDIENUNGSANLEITUNG 5 65 123 PL EN DE...
Page 4: ......
Page 33: ...33 Polski 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Instalacja sterownika na cianie...
Page 63: ...63 Polski...
Page 64: ......
Page 91: ...91 English 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Installing controller on the wall...
Page 121: ...121 English...
Page 122: ......
Page 149: ...149 Deutsch 1 2 3 4 1 2 3 4 60 9 10 8 10 9 57 56 Installation der Wandbedieneinheit...
Page 179: ...179 Deutsch...
Page 180: ...kaisai com...