4. Fill with cooling oil.
5. Check the filler plug and ring seal for damage and screw the plug back in again.
Starting the machine and performing a trial run
1. Close all access doors, replace and secure all removable panels.
2. Open the user's shut-off valve between the machine and the air distribution network.
3. Switch on the electrical power supply via the power supply isolating device and reset the main‐
tenance interval counter.
4. Start the machine and check the oil level again after about 10 minutes, topping up if necessary.
5. Switch off the machine and check for leaks.
10.17 Changing the oil filter
The machine must be isolated from the compressed air network and completely vented be‐
fore undertaking any work on the pressure system.
Material Spares
Cooling oil receptacle
Precondition The power supply isolating device is switched off,
the device is locked off,
the absence of any voltage has been verified.
The machine is fully vented,
the pressure gauge on the oil separator tank reads 0 bar.
CAUTION
There is risk of burns from hot components and oil!
➤ Wear long-sleeved clothing and gloves.
Fig. 35 Changing the oil filter
1
Oil filter
2
Direction to unscrew
10 Maintenance
10.17 Changing the oil filter
901824 12 E
Operating Manual Screw Compressor
ASK
79
Summary of Contents for ASK 28
Page 2: ...Original instructions KKW SASK 2 22 en SBA SCHRAUBEN SC2IO KKW SSC 2 08 20170919 084918...
Page 6: ...Contents iv Operating Manual Screw Compressor ASK 901824 12 E...
Page 8: ...List of Illustrations vi Operating Manual Screw Compressor ASK 901824 12 E...
Page 138: ...13 Annex 13 4 Electrical Diagram 128 Operating Manual Screw Compressor ASK 901824 12 E...