10.2 Following the maintenance plans
10.2.1 Logging maintenance work
The maintenance intervals given are those recommended for KAESER original components
with average operating conditions.
➤ In adverse conditions (e.g. oil and filter changes), perform maintenance work at shorter
intervals.
Adverse conditions are, e.g.:
■ Poor fuel quality
■ High/low temperatures
■ Much dust
■ Frequent use
➤ Adjust the maintenance intervals with regard to local installation and operating condi‐
tions.
➤ Logging all maintenance work.
This enables you to determine the frequency of individual maintenance tasks and deviations
from our recommendations.
Further information A list is available in chapter 10.9.
10.2.2 Maintenance tasks after commissioning
The table below lists maintenance tasks required after commissioning (initial start-up).
➤ Carry out maintenance tasks according to the following schedule.
Component:
Task
After the first 50 h
After the first half year (250 hours)
See chapter
Note
Engine:
Check the fuel lines and clamps.
X
KS, FW
–
h = operating hours
KS ≙ Contact KAESER SERVICE,
FW ≙ Contact specialized workshop.
Tab. 82 Maintenance tasks after commissioning
10.2.3 Regular maintenance tasks
The following table lists the various maintenance intervals.
Maintenance interval
Short description
Daily
–
Every 250 h, at least annually.
A250
Every 500 h, at least annually.
A500
10 Maintenance
10.2 Following the maintenance plans
No.: 9_9547 13 USE
Operator Manual Screw Compressor
MOBILAIR M27
87