Fig. 13 Minimum distance from excavations, slopes, or walls
1. Keep sufficient distance (at least 5 feet) from the edges of excavations, slopes, and walls.
2. Ensure that the machine is as level as possible.
The machine can be temporarily operated on a slope of not more than 5°.
3. Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
4.
Danger of burning from build up of heat and hot exhaust!
Insufficient distance from a wall may cause heat build up that could damage the machine.
➤ Do not position the machine directly against a wall.
➤ Always ensure sufficient ventilation space around the machine.
5. Position the machine as far as possible from any wall.
6. Ensure there is enough free space all round and above the machine.
7. Keep air inlet and outlet openings free of obstructions so that the cooling air can flow freely
through the machine.
8. Position the machine in such a manner that:
■ wind does not blow into the cooling air outlet.
■ exhaust gases and heated cooling air can not be drawn into the compressor.
5
Installation and Operating Conditions
5.2
Installation conditions
54
Operator Manual Screw Compressor
MOBILAIR M27
No.: 9_9547 13 USE