Maintain the following minimum distances to the object to be cleaned in order to prevent damages
to the machine when cleaning with the high-pressure cleaner.
■ Circular section jets: approximately 2.3 ft
■ Fan jets: approximately 1 ft
■ Dirt blasters: approximately 1 ft
Keep the water jet in permanent motion during the cleaning process. You prevent thus dam‐
age.
Cleaning with dry-ice jets is strictly forbidden as it could cause unforeseeable damages.
1.
Machine damage caused by strong water jet!
Direct water jets can damage or even destroy sensitive components.
➤ Do not directly focus a strong water jet towards sensitive components.
➤ Work carefully.
2. Carefully clean the machine with the high-pressure cleaner.
Water has accumulated in the sealed floor pan.
➤ Drain the water.
Catch the liquid and dispose in accordance with applicable environmental regulations.
Further information See chapter 10.8.7 for information to the draining of liquids within the machine.
8.5 Operating the options
➤ Comply with all instructions.
8.5.1 Option oa
Operating the battery isolating switch
Danger of short circuit!
Damage to the machine electrical system is possible.
➤ Use the «Battery isolating switch» only when the machine is switched off.
➤ Do not use the «Battery isolating switch» as a main or emergency switch!
8
Operation
8.5
Operating the options
70
Operator Manual Screw Compressor
MOBILAIR M27
No.: 9_9547 13 USE