5. Insert a new filter element.
Wear gloves!
6. Screw on the filter housing clockwise.
Changing the pre-filter element
1. Unscrew the filter housing counterclockwise.
2. Draw the filter element down and out.
3. Clean the filter head, housing and sealing surface with a lint-free cloth.
4. Check the gasket.
Gasket damaged: replace gasket.
5. Insert a new filter element.
Wear gloves!
6. Screw on the filter housing clockwise.
Putting into operation
Fig. 58 Filter combination
1
Filter combination
2
Pre-filter
3
Shut-off valve, pre-filter
4
Lever for shut-off valve, pre-filter
5
Micro-filter
6
Shut-off valve, fine filter
7
Lever for shut-off valve, fine filter
1. Screw the condensate drain hoses to the housings of the pre-filter and the micro-filter.
2. Close the shut-off valve of the pre-filter.
The lever of the shut-off valve is positioned transversal to the flow direction.
3. Close the shut-off valve of the fine filter.
The lever of the shut-off valve is positioned transversal to the flow direction.
10 Maintenance
10.8 Maintenance for Optional Items
No.: 9_9547 13 USE
Operator Manual Screw Compressor
MOBILAIR M27
145
Option dd