Decommissioning of the compressor for several weeks during severe frost
1. CAUTION!
Danger of batteries freezing.
Discharged batteries are subject to frost damage and can freeze at −10 °C.
➤ Store batteries in a frost-free place.
➤ Store batteries preferably fully charged.
2. Remove the battery (batteries) and store in a frost-free room.
3. Make sure batteries are fully charged.
12.1.2 Long-term decommissioning
Decommissioning the machine for 5 months or longer.
Material Receptacle
Preserving oil
Preservative
Desiccant
Plastic foil
Moisture-resistant adhesive tape
➤ The following measures must be taken for long-term decommissioning.
Long-term decommissioning tasks
See chapter Confirmed?
➤ Check engine coolant level.
10.3.1
➤ Draining the engine oil
Engine SM
➤ Draining the cooling oil from the separator tank and oil cooler.
10.4.3
➤ Filling the engine and oil separator tank with preserving oil.
Engine SM
10.4.2
➤ Run the machine for about 10 minutes to coat all parts with a pro‐
tective oil film.
–
➤ Disconnect the battery, the minus terminal first and then the plus
terminal, and store in a frost-free room.
–
➤ Check the battery fluid level.
10.6
➤ Check the battery charge monthly and recharge if necessary to pre‐
vent the battery fluid freezing.
–
➤ Clean the battery terminals and coat with acid-resistant grease.
–
➤ Close the compressed air outlet valves.
–
➤ Cover the following openings with plastic foil and moisture-proof ad‐
hesive tape.
– Engine air intake
– Compressor air intake
– Exhaust discharge
–
➤ Clean the bodywork and treat with a preservative.
–
Engine SM = engine manufacturer's service manual.
12 Decommissioning, Storage and Transport
12.1 De-commissioning
No.: 9_9432 02 E
Service Manual Screw Compressor
M43
193
RAMIRENT