Country-
spec. Set-
tings
Men
u
level
Display/
Setting
Action in this menu/meaning
4
1
2
3
4
Date & time
NOTE: For self-diagnostics, the device performs a restart on a
daily basis at 0:00 hours. To avoid having a restart occur dur-
ing feed-in operation and to always obtain reliable log data,
ensure that the time is correctly set.
F
Set the date and time.
4
1
2
3
4
Network
Open the menu: Press the
Right arrow button
or
Enter but-
ton
.
4
1
2
3
4
DHCP
On / Off
NOTE: The "IP address", "Subnet mask", "Gateway" and "DNS-
Server" menu options are only displayed with DHCP disabled.
F
Activate or deactivate DHCP.
On
: Once the DHCP server becomes available, the IP address, subnet
mask, gateway and DNS server are automatically applied and the afore-
mentioned menu options are hidden.
Off
: Apply settings manually.
4
1
2
3
4
IP address
F
Allocate a unique IPv4 address in the network.
4
1
2
3
4
IP address
NOTE:
The “IP address”, “Subnet masks”, “Gateway” and “DNS server”
menu items
are only displayed with DHCP disabled.
4
1
2
3
4
Subnet mask
F
Assign a subnet mask.
4
1
2
3
4
Gateway
F
Enter IPv4 address of the gateway.
4
1
2
3
4
DNS server
F
Enter IPv4 address of DNS server.
4
1
2
3
4
Webserver
F
Open the menu: Press the
Right arrow button
or
Enter
button
.
4
1
2
3
4
Operation mode
F
Activate or disable the integrated web server.
4
1
2
3
4
Port
F
Set the port at which the web server can be reached.
4
1
2
3
4
Remote config
On / Off
F
If necessary, activate the remote configuration.
4
1
2
3
4
Remote update
On / Off
F
If necessary, activate the remote update.
4
1
2
3
4
Portal Connection test
Off | Meteocontrol |
User-defined 1-4:
↻
Your IT infrastructure must be adequately protected.
F
Select operating mode.
Off
: The connection to the portal is deactivated.
Meteocontrol
: The device attempts to connect to the Webportal blue-
planet web of meteocontrol.
User defined 1-4
: The device attempts to log on via a user-defined
portal that was set up by way of remote access.
4
1
2
3
4
Modbus TCP
F
Activate/disable function.
4
1
2
3
4
Activation
.
NOTE: The menu options "Write access" and "Port" are
only displayed with TCP activated.
1. Activate Modbus TCP.
4
1
2
3
4
Write access
F
Allow Modbus TCP write access.
4
1
2
3
4
Port
F
Set network port.
4
1
2
3
4
Connection status
Indicates the status of the network connection.
9 | Configuration and operation
Manual
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
Page 38