Country-
spec. Set-
tings
Men
u
level
Display/
Setting
Action in this menu/meaning
4
1
2
3
4
Save to USB
NOTE: Opportunity to export the operating data to a connec-
ted USB storage device.
↻
You have connected a USB storage device to the device.
1. Select the data to be exported (year, month or day).
2. Press the
Enter button
.
ð
The device writes the data to a connected USB storage device.
4
1
2
3
4
Settings
F
Open the menu: Press the
right arrow
or
enter
button.
4
1
2
3
4
Language
F
Select the required language for the user interface.
4
1
2
3
4
Define total yield
NOTE: You can set the total yield to any value, for example,
when you have received a replacement device and want to
continue the recording from the present value.
F
Select the
Save
button and confirm with the
Enter button.
4
1
2
3
4
Interface
NOTE: The address must not be the same as the address of an-
other device or a Powador-proLOG device
.
F
Assign a unique RS485 bus address to the device.
4
1
2
3
4
Priwatt
F
Open the menu: Press the
Right arrow button
or
Enter
button
.
4
1
2
3
4
Activation mode
NOTE: Re-activation depends on the operating mode selected
and on the activation conditions.
F
Activate function for a cycle
4
1
2
3
4
Monitoring time
F
Set time span during which the power threshold must be exceeded
without interruption.
4
1
2
3
4
Power threshold
F
Set power threshold from which the monitoring time up to activation
begins.
4
1
2
3
4
Operation mode
1. Power-dependent: the function remains active until below the set
power threshold.
2. Time-dependent: The function is active independent of the sunlight
for the set operation time.
4
1
2
3
4
Operation time
NOTE: The menu option is only available in "Time-dependent"
operation mode.
F
After connection, the function is active for the set operation time.
4
1
2
3
4
Quick start
F
Reduce the waiting times during the self-test by pressing
the
Activate
button.
4
1
2
3
4
Logging interval
F
Specify the time period between 2 log data recordings.
4
1
2
3
4
Log data backup
NOTE: The device supports the backing up of all recorded
yield data to a connected USB storage device.
F
Activate or deactivate log data backup
4
1
2
3
4
Display
1. Configure the contrast setting for the display.
2. Set the length of time without user input after which the backlight-
ing of the LCD switches off.
3. Alternatively: Permanently activate or disable the backlighting by
selecting "
On
" or "
Off
".
Manual
Configuration and operation | 9
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
Page 37