Operating instructions
3
COMMISSIONINg
Warning:
Prior to commissioning, make sure that the door installation has not been
subject to any modifications which might cause dangerous situations:
• Check the door surroundings for any structural changes.
• Make sure that no objects (such as furniture, pallets, etc.) have been
placed close to the door.
3.1
Sequences
1. Check if all the drive elements and
options have been cabled (see con-
nection diagram in the appendix).
2. Checking/setting of the DiP swit-
ches:
See chapter „Settings“.
3. Switch on power supply system.
4. Select the operating mode AuTOmA-
TiC: the setting-up run.
note:
The door must close first. When it opens first: Check right position of belt
coupling(s) or change sense of rotation of the gear motor.
The setting-up procedure is only carried out in the mains-powered mode,
whereas no setting-up is possible in the emergency battery mode because of
the restricted battery power. The control unit STere is automatically swit-
ched off.
if the sliding wing weight
exeeds 20 kg
, all the setting values remain memo-
rized after a mains failure (no learning run upon start-up).
5. Adjust all the radars and presence detectors according to the respective instructions.
6. Set the desired parameters.
7. Check the function.
Adjusting trimmers