5.3
Paratmeter settings
for the setting procedure the following parameters are learned
:
Travel distance
When pushing against the close stop piece, first the CLOSED position is reliably recog
-
nised. Afterwards the open stop piece is searched out in creeping speed.
Door mass
With a short acceleration the mass of the slide wing(s) is measured. Out of it result the
maximum speed, creepage distance and forces.
Recognition of mechanical emergency opening MeNO
in CLOSeD position the locking pressure is switched-off for a short time. if door moves
towards the OPen position, it can be gathered that there is a mechanical emergency
opening menO.
5.3.1
Settin-up procedure in special conditions
Obstacle
if the slide wings are impeded during the setting-up procedure, this position is recognised
as travel stops. Therefore a new setting-up procedure will be necessary.
Workshop setting-up procedure (without sliding wing)
if the sliding wings weight is less than 20 kg
, setting-up procedure data is not saved (ex
-
cept BAT-nOT). When switching back on, a reset is activated. This allows to install drive
mechanism components and to carry out the operating test in the workshop.
if the sliding wings weight is more than 20 kg, after a power failure, all setting parameters
remain saved (on activating no learning run).