Page 29 of 46
Operating instructions
7.1
Service for pedestrian doors
Warning:
electrocution hazard! Before working on any live elements, pull out the
mains plug as well as any existing plug of the emergency battery respective
-
ly switch off the main installation switch!
Basis: QS-CL P.05.05.113.4
maintenance for pedestrian doors
Check
Clean
Grease
Adjust
Installation
General condition
x
Free door movement (manually)
x
x
Door guides/guideway rails
x x x
Door sealing joints
x x x
Side panels/protection wings
x x
Coverings/hinge-type covers
x x
Check tight fitting of the screws and nuts
x
Clean the installation
2
x x
Drive mechanism
Drive mechanism
x x x
Holding power in CLOSED position
x
Transmission elements such as:
toothed belt, flat belt, cables, rods or chains
x x x
Carrying rollers/counter-pressure rollers, running carriages
x x x
Carrier rails
x x x
Open/Closed positions
x
x
Control
Electrical connections
x
Control functions
x
x
Program switch (BEDIS, BEDiX, etc.) check all the positions
x
Emergency battery
x
emergency opening (pull out both power plugs of the AnTe‘s)
1
x
Control elements
All the existing control elements such as:
sensor, radar, key-operated switch, contact carpet, etc.
x x x
Safety elements
Reversing/stopping mechanism
x x x
Door locking/manual unlocking mechanism
x x x x
Mechanical emergency opening
x
x
Monitoring switch
x x x
Light barrier/Presence detector
x x
Existing additional safety elements
x x x
minimum escape way width
1
x
x
Miscellaneous
Stickers/rating plates
x x
1
Only for redundant drive mechanisms
2
kABA Gilgen cleans all the elements of the installation provided this is necessary for the function of the instal-
lation. A general cleaning of the installation is not planned.