0639-990-21---30j_2010.07.indd
SLA
0639-990/22j
Page 36 of 46
Operating instructions
8.4.7
Specific BAT-NOT errors
no.
1601
1602
1603
Description
Test opening with emergency ope-
ning rubber cable not successful
during the setting-up procedure.
Excessive tension of emergency
opening rubber cable (operation).
Excessive tension of emergency
opening rubber cable (setting-up).
Corrective action
Check the emergency opening rubber cable, check
respectively make sure that the sliding wings can
be easily moved.
Without D-BeDiX the door remains open.
reduce the tension.
reduce the tension.
fatal error (door remains open).
mode
niGhT
Closure
possible
yes
yes
yes
8.4.8
Operative messages (informative)
no.
2000
Description
more than 5 successive
obstructions.
Corrective action
remove the obstacle.
mode
niGhT
Closure
possible
yes
8.4.6
Mounting and setting errors
no.
1000
1001
1002
1007
Description
reset has been triggered (purely
informative message).
• Minimum opening width has not
been reached during setting-up.
• No mass measurement.
• No Reset carried out after DIP1
changing.
reset not possible in battery-
operated mode.
A sliding wing weight of <20 kg was
measured.
Corrective action
-
remove the obstacle, check/restore the free
running movement of the sliding wings, check the
locking, carry out a reset.
Plug in the mains connector.
Check the sliding wing and the toothed belt cou-
pling.
mode
niGhT
Closure
possible
-
no
no
yes