5
Lock Maintenance
Once you have receive the “battery Low” indication of ten
fast yellow flashes after a valid combination entry, you
should change the batteries in a reasonable amount of time.
Remove the two screws from the battery panel and then
remove the panel. Remove the CR-2 Lithium 3V batteries
and replace with high quality, name brand batteries
(Energizer
®
or Duracell
®
.) The negative (-) end of the
battery should be inserted into the battery cavity first.
WARNING:
The lock MUST NOT be sprayed with water or any cleaning liquid.
Recommended cleaning is to wipe down the lock using a damp cloth or a
towelette. Alcohol is an acceptable disinfectant for medical environments.
Initial Lock Operation
To test successful installation of the lock before you begin lock setup, perform the
following operation.
WARNING:
The container door should remain open until testing is complete.
To Lock/Unlock Using the Master/Manager Pre-Set PINs
Your lock has been shipped so that
any valid Master or Manager User ID for the
lock model followed by the factory pre-set PIN for that User ID will lock or unlock
the lock.
Lock the Lock - Master/Manager Pre-Set
1.
If necessary, turn the lock knob counter clockwise (CCW) to the “locked”
position.
2.
Press and hold the
key until the yellow light
Y
displays.
3.
Enter any valid three-digit User ID for the lock model followed by the default
factory PIN for the User ID. ( For
User ID 111
the default PIN is “
12345
”. For all
other Users IDs the default PIN is “
55255
”. )
If the combination is entered successfully, the lock displays one green flash
G
with a beep
to indicate that a valid combination has been entered. One long
green flash
G
displays with a beep
to indicate that the motor has fired and
the lock is in the “locked” state. A long red flash
R
is displayed with a beep
to indicate that the knob is in the closed position and the lock is locked.
Note:
A “combination locked state” audit record is written at this point followed by a “lock
close” audit record if the knob is in the “locked” position. If the knob is not fully
turned CCW to the “locked” position, the long red light
R
will not display at the end
of the operation and the “lock close” record will not be written.
Battery Panel
+
+
-
-