15
Download Data from Lock
There are two types of data that can be “downloaded” (retrieved) from the Unicon
CL10 locks.
Note:
Data cannot be retrieved from the lock when in Shelved Mode.
Retrieve Audit Records
The lock’s audit feature will track the following types of lock transactions in sequen-
tial order of occurrence:
•
lock date/time set
•
users added/deleted
•
PIN activated/changed
•
lock opened
•
lock closed
•
combination locked state
•
wrong try penalty
•
lock shelved
•
audit report retrieved
•
user table report retrieved
Each audit record will include a description of the event, the user who initiated the
activity (if applicable) and the date and time stamp. The number of audit records
stored by the lock is 400. If you have purchased the Unicon CL Series Software, the
audit trail data stored in the lock can be downloaded from the lock and taken to the
PC for reporting.
Note:
The retrieve audit records operation requires a red reporting key fob that has been
initialized using the PC software to retrieve audit records. When an audit is
retrieved, it will overwrite any previously existing audit data that is in the key fob.
1.
Press
#
Y
and then
2
.
G
R
2.
Enter the combination. Short red flashes with beeps
R
begin to display.
From the time these flashes begin, you have 20 seconds to properly insert the
prepared red reporting key fob into the lock key fob reader. If you do not
properly insert the key fob within the 20 second period, short red flashes
followed by three red flashes display with beeps
R
R
R
to indicate
an error and you will need to re-key the operation. If the reporting key fob has
not been properly initialized, three red flashes display with beeps
R
R
R
.
3.
Ensure that the key fob remains connected to the key reader until the lock
has completed downloading the reporting data. Upon completion, two
simultaneous green and red flashes display with beeps
G
R
G
R
indicating that the audit data download is complete.