1
Programming Reference
1.10HCU / LSR loader set-up
Page 56
Docu-No.: 0590020601-EN Rev. 1.6.0
1.10
HCU / LSR loader set-up
This menu programs the Hurricane loader function. This menu is used
in place of the HSU.
• This menu is only displayed, if a HCU / LSR is connected.
• The HCU / LSR Loader controller is connected to the KCM via the
Internal Channel.
• Be sure that the LOADER parameter is <disabled> in the LOADER
menu. Hide the LOADER menu.
• See manual 0290023601 for more HCU loader operational
information.
• See KCM Electronics manual for more information.
• See manual 1090034605 for more LSR operational information.
Parameter
Definition
COMMAND
Loader Command
The following commands can be selected and be executed with the
ENTER
key:
None No
function
Run
Starts the conveying cycle
Stop
Stop the conveying cycle
Clr Alrm
Deletes all pending alarms
Disch On
Starts discharge
Disch Off
Stops discharge
▲
Conveying starts if you press
ENTER
at the selection <RUN>.
The process can be stopped only by selection of the command stop.
The
START/STOP
key on the control unit does not have a function
for the loader.
CYCLE
Active Cycle
Displays the current active cycle.
Motor
Motor Timer active. After the timer expired the
motor will stop.
LoadDly
Delay until the valve is closing and a new
conveying cycle is starting.
Load
Hurricane is conveying material.
Line Clr
Conveying pipe emptying cycle is active.
DischDly
Discharge delay time. Delay = Time until the motor
stops.
Disch
Discharge cycle: Display only.
Input range: Display only
Table page 1 of 2