Docu-No.: 0590020601-EN Rev. 1.6.0
Page 11
Programming Reference
1
Product change menu 1.1
1.1
Product change menu
This menu allows easy product changeover. See section
•
for
manuals to be used specifically when calibrating the feeder.
1.1.1
Product change parameters
Parameter
Definition
REFILL
Refill Enable
ENABLED
Setting for automatic refill. The net weight alarm
limit is active.
DISABLED
The feeder hopper can be emptied without refilling
being triggered. The net weight alarm limit is
disabled.
IF RUNNING
Refill is enabled if the feeder runs, otherwise it is
disabled.
Default: DISABLED
REFILL MAX.
Refill Level Maximum
Input of the upper refilling limit at which refilling is stopped.
Warning:
Do not exceed the hopper capacity or scale capacity when entering
the top refilling limit. See section
.
Input range: <0.95 x Gross scale range
Default: 0.06 kg
REFILL MIN
Refill Level Minimum
Input of the lower refilling limit at which refilling is started. See section
.
Warning:
Feeding behavior can be affected if the refilling limit is set too low.
Do not uncover feeder horizontal agitator.
Input range: < Refill Maximum
Default: 0.05 kg
START REFILL NOW
This command starts the refill when the net weight is less the
<REFILL MAX>.
Table page 1 of 5