Product change menu 1.1
ACTIFLOW CALIB
ActiFlow calibration function
1. Fill the feeder with material.
2. Set material characteristic “Easy, Medium, Hard or Manual“ in
the KCM ActiFlow menu.
3. Run the ActiFlow calibration.
Notes:
• This calibration routine will run a frequency sweep on the ActiFlow
to find the mechanical resonance point of the feeder. During the
calibration is no material fed.
• Its important to have the feeder filled with material to a normal
operating level before running this step, because the resonance
point is significantly affected by material.
SCREW FILL
When started, the motor will run (At the Calib DC) until weight loss is
detected. Then the motor automatically stops.