17
Post Trigger Mode
If post trigger mode is configured, activity commences once the following trigger conditions
are met:
• The analog input channel acquires a programmed number of samples at a specified
sampling rate
• The analog output channel outputs pre-defined voltage at a specified output rate
Figure 3-6: Post-Trigger Acquisition
Delay Trigger Mode
If delay trigger mode is configured, delay time from when the trigger event asserts to the
beginning of the acquisition and waveform generation can be specified, as shown. Delay
time is specified by a 32-bit counter value with the counter clocking based on the PCIe clock.
Accordingly, maximum delay time is the period of PCIe_CLK X (2^32 - 1) and minimum is the
period of PCIe_CLK (8 ns).
Time
Operation
start
Trigger
Data
Trigger Event
Occurs
Acquisition stop
Begin to transfer data to
system
N samples
Acquisition start
Delay Time
Figure 3-7: Delay Trigger Mode Acquisition
Post-Trigger or Delay-Trigger Acquisition with Re-Trigger
Post-trigger or delay trigger acquisition with re-trigger function enables collection of data
after several trigger events, as shown. When the number of triggers is defined, the PXIe-
69529 acquires specific sample data each time a trigger is accepted. All sampled data
is stored in onboard memory first, until all trigger events have occurred, such that time
between the previous sampled data and the subsequent trigger event can be only one clock