34
Manual Adjustment of White Balance (Continued)
CAUTION:
The color temperature will be slightly af-
fected when the dome cover is attached.
Pay attention to this when adjusting the
white balance manually.
– – M A N U
L
WH I T E
B A L A N C E – –
A
:
R
- -
- - - - - - - - - - -
+
g :
M
- - - : B
- -
- - - - - - - - - - -
-
-
+
- - : G
E N D
Setting indicating mark
Original position
2.
Select the hue to be adjusted. (R/B or
Mg/G)
When operating using the camera
body, press the UP or DOWN button.
When using the RM-P2580, press the
PAN/TILT control lever upward (
6
) or
downward (
7
).
3.
Adjust the hue.
When operating using the camera
body, press the LEFT or RIGHT
button.
When using the RM-P2580, press the
PAN/TILT control lever to the left (
8
)
or to the right (
t
).
• The “+” indicator moves in accordance
with the setting. When a setting is
changed, the “
9
” mark appears at the
original position.
4.
Concluding manual white balance
adjustment.
When operating using the camera
body, press the UP or DOWN button
to align the cursor (>) with the END
item. Then press the SET button.
When using the RM-P2580, press the
MENU button or use the PAN/TILT
control lever to align the cursor (>) with
the END item and then press the SET
button.
• The VIDEO ADJUST screen returns.
– – M A N U
L
WH I T E
B A L A N C E – –
A
:
R
- -
- - - - - - - - - - -
-
g :
M
+
- - - : B
- -
- - - - - - - - - - -
-
-
+
- - : G
E N D
WHITE BALANCE
adjustment screen
SETUP MENU
35
AWC (One-push Auto White Balance) Adjustment
Using a simple operation, the AWC function
allows the white balance to be fixed as the
one valid at a given point. Used for observa-
tion when the color temperature changes fre-
quently.
1.
The following two methods are available
for activating the AWS function.
1
Press the UP (AWC) button on the
camera body for about 1 second
while the normal screen (no setup
menu shown) is displayed.
or
2
Set the WHITE BALANCE item on
the VIDEO ADJUST screen to AWC
and press the SET button. (Possible
both on the camera body and the
RM-P2580).
2.
When the AWC function is activated,
“AWC OPERATION” is displayed at the
bottom of the monitor screen.
3.
The result of the AWC operation is
displayed on the monitor screen for
approximately 5 seconds. Then the
screen displayed before the AWC
function was activated returns. (Normal
screen or VIDEO ADJUST screen)
Operation result indication
AWC OK
: Completed
normally
AWC NG : OBJECT
: The color
temperature is
outside the
tracking range
AWC ERROR : HIGH LIGHT : Excessive
brightness
AWC ERROR: LOW LIGHT
: Insufficient
brightness
MEMO:
The AWC function invoked by the UP
(AWC) button on the camera body starts
up regardless of the setting of the WHITE
BALANCE item on the VIDEO ADJUST
screen.
MONITOR
LOCK
LEFT
RIGHT
SET
UP
AWC
DOWN
LEFT button
RIGHT
UP(AWC) button
DOWN
NOT USED
NOT USED
L/L
ON
INT
OFF
TERMINATION
AWC
– –
I D E O
A D J U S T – –
V
I R I S
L E V E L
N O R M A L
N O R M A L
N O R M A L
C O L O U
L E V E L
R
E N H A
C E
L E V E L
N
A G C
O D E
2 0 d B
M
S U P E
A G C
O F F
R
B L C .
O F F
.
A V E R
G E : P E A K
8 : 2
A
E N D
WH I T
B A L A N C E
A W C
E
VIDEO ADJUST screen
A WC
O P E R A T I O N
AWC
A WC
O K
A WC
N G : O B J E C T
Indication in case of abnormality
Indication when operation is completed normally.
Blinks
During AWC operation
Summary of Contents for TK-C553E