LX-D1010G
(PA012) 14-1
14. CONNECTOR TERMINAL FUNCTIONS
1) Main PWB Assy
E
To Lamp Power Unit
Connector
SA-CB2
Signal Name
IN / OUT
Function / Summary
Remark
1
LAMPON
OUT
Lamp on signal (H: ON)
H: 4V / L: 0V
2
DGND
3
LSENSE
IN
Lamp-on was failed (
C
: failed, L: succeeded)
L: 0V (failed H: 5V)
E
To Power PWB Assy
Connector
SA-CB2
Signal Name
IN / OUT
Function / Summary
Remark
1
AGND
2
SW15.5
IN
Switched Power 15.5V
15.5V
3
AGND
4
SW12
IN
Switched Power 12V
12V
5
AGND
6
SW5A
IN
Switched Power 5V
5V
7
AGND
8
STBYR5
IN
Standby Power -5V
-5V
9
AC-DOWN
IN
Power failure detect
10
P-ON
OUT
P-ON signal ( H: POWER OFF, L: POWER ON )
H: 5V / L: 0V
11
FAN-ON
OUT
FAN-ON signal (H: FAN ON, L: FAN OFF)
H: 5V / L: 0V
12
13
E
To Power Sub PWB Assy
Connector
SA-CB2
Signal Name
IN / OUT
Function / Summary
Remark
1
FGND
GND for fans
2
FANV
IN
Power for FAN
7-13V
3
P-FANC
OUT
POWER FAN CONTROL
0-4V
4
O-FANC
OUT
OPTICAL FAN CONTROL
0-4V
5
DGND
GND for digital circuit
6
STBY5
IN
Standby Power 5V
DC 5V
7
DGND
GND for digital circuit
8
SW5D
IN
Switched Power 5V
5V
9
DGND
GND for digital circuit
10
SW3.3
IN
Switched Power DC 3.3V
3.3V
11
P-FSTOP
IN
FAN LOCK SENSOR for power fan
(L: normal, H: abnormal)
12
E
To Blower (intake)
Connector
SA-CB2
Signal Name
IN / OUT
Function / Summary
Remark
1
IN-FGND
GND for Blower
2
IN-FANV
OUT
Power for Blower
7-13V
3
IN-FSTOP
IN
Fan lock sensor for Blower (L: normal / H: abnormal) 0V / 5V
Summary of Contents for LX-D1010G - Lcd Projector
Page 32: ...LX D1010G 4 10 PA012 Memo ...
Page 36: ...LX D1010G 6 2 PA012 Memo ...
Page 67: ... PA012 15 1 LX D1010G 15 BLOCK DIAGRAMS ...
Page 68: ... PA012 15 2 LX D1010G ...
Page 69: ...LX D1010G PA012 15 3 ...
Page 70: ...LX D1010G PA012 16 1 ...
Page 77: ...LX D1010G PA012 Parts 7 Memo ...
Page 81: ...しろページ ...