E19
Connecting a monitor
Connect the PC monitor (VGA) to the MONITOR terminal on the rear of the main unit.
SEE INSTRUCTION MANUAL
POWER
DC IN
REMOTE
MONITOR
LENS
FREEZE
PLAY
SET
DOWN
AW/SEL
SEND
SCSI
UP
MENU
MODE
REC
ON 1 2 3 4
MONITOR terminal
MEMO
• The monitor cable must use clump filter for both ends to minimize emission of unwanted electrical
waves. (Commercially available VGA video cable is recommended)
• For the pin assignment, see page 13 Pin configuration of connectors
• Monitor conditions:
fH: 31.47 kHz
fV: 59.94 Hz
Sync signal: H/V separate, TTL negative polarity
• Dip switch setting (
page 24)
VGA mode (set dip switch No. 3 to OFF)
Do not connect the unit to a VGA monitor directly when in the SXGA mode (dip switch No. 3 ON)
CAUTION
• Before connecting, make sure that the power of all systems are turned off. Connecting with the power
turned on may result in malfunction.