E12
1
4
3
6
7
8
5
2
1. Introduction (continued)
Power terminal (Mini DIN 8-pin, female)
Pin configurations of connectors
Pin no.
Signal name
1
NC
2
GND
3
NC
4
NC
5
GND
6
12V
7
NC
8
12V
Lens terminal (Metal 12-pin, female)
Pin no.
Signal name
1
NC
2
FREEZE
3
GND
4
NC
5
IRIS CONTROL
6
12V DC
7
IRIS POSITION
8
IRIS AUTO /MANU
9 to 12
NC
6
7
8
2
1
9
3
4
12
5
10
11
Terminal
name
FREEZE
WEN
FLASH
Remote terminal (Metal 10-pin, female)
Pin no.
Signal name
1
A. WHITE L active Zi=22k
Ω
2
FREEZE L active Zi=100k
Ω
3
WEN L active Zo=22
Ω
3.3V(p-p)
4
FLASH
5
SEND
6
RS-SDI
7
RS-SDO
8
GND
9
12V
10
OPERATION
1
2
8
7
10
6
3
4
5
9
CAUTION
• Consult your JVC dealer concerning the re-
mote terminal connection.
• Remote cable must use shielded cable.
Outer shield of remote cable must to connect
10-pin connector outer metal shell.
* However, insert a diode as shown in the dia-
gram below.
I/O
IN
• 5V CMOS
• Schmidt Trigger
• Pull-up to 5V at
100k
Ω
OUT
• 3.3V (p-p)
negative polarity
OUT
• Open collector
Conditions
• Contact point
recommended
• Maximum rated
voltage: 5.3V
• H level: 3.5 ~ 5.0V
• L level: 0 ~ 0.8V
• CMOS (5V): OK*
• TLL not possible
• Pulse width:
130
µ
s or higher
• Output only when
in the SXGA mode
• Maximum rated
current: 150mA
• Maximum rated
voltage: 12V
KY-F70B
C Mos IC