8. Check the sector positions are working
After recording all the sector end points, return to sector 1 and place a
short somewhere on Sector 1. Check that energizer reports Sector 1. If
you are close to the end of sector 1 energizer may report Sector 1 and 2
(alternating).
9. Restore the alarm settings
Remember to set and check the
Voltage Alarm 1, Anti-bridging
settings
back to their original values you had.
If you removed siren wiring in step 3 and or inhibited the onboard beeper
(J5) restore them to their correct settings and check that they operate.
NOTE: If after sector programming the fence, it is altered (wires added or
removed) or sector dividers are added, each individual sector can be al
-
tered to adjust for the change in fence behaviour.
12.2 SITE SECTOR RECORD
Recording the actual sector split positions will help in fault finding later
Sector
End
Position
(% of total
fence length)
Feed 1 Cur
-
rent (Amps)
Feed 2 Cur
-
rent (Amps)
Fence Volts
(kV)
1
2
3
4
5
6