Mode
Trigger Condition
Host Control
This Relay is completely controlled from a Host sys
-
tem such as Perimeter Patrol or a Keypad. If the Host
system is disconnected from the Energizer for more
than 30 seconds, the Relay will automatically change
to the Alarm State
Host Control -
Not Fail Safe
This Relay Host Controlled however if the Host system
is disconnected then the Relay will maintain its cur
-
rent state
Group Armed
Triggers when group is armed. Only configurable on
group master
Group General
Triggers on group general alarm. Only configurable on
group master
Note 1: The siren and strobe switched 12V outputs can be used to drive
external buffer relays.
11.30 PROGRAMMING WITH THE VIRTUAL KEYPAD
The Virtual Keypad provides an easy solution for programming the JVA JMB
series energizers.
To access programming mode, ensure you are connected to the energizer
and see the main webpage on your Virtual Keypad. At the bottom click on
the
Device Setup
button and enter the Installer Password. Press the
Login
button when you have entered the password.
The default Installer Password is
12345
.
You will now be redirected to the Configuration page.