10 .3 .3
Sector Divider
In order to maintain the highest level of sector reporting accuracy a Sector
Divider may be wired between sectors on the fence. This is required when
one or more of the sectors is very short and is also recommended between
sectors which differ in construction, for example between wall top and
free-standing sectors.
Note: When programming the sector splits into the JMB energizer, place
the short to ground on the mid (normally unused) terminal of the Sector
Divider. This means that the sector split is recorded at the theoretical mid
-
point inside the divider and any real fence short will always be outside.
10.4 LOW VOLTAGE TERMINALS
If no battery is connected, the combined power for all 3 outputs can only
be less than 0.5A.