24 | Juniper Networks, Inc.
Electrical Specification
AC voltage: 90-264 VAC
AC Watts: 12 Watts
DC voltage: N/A
Environmental
The maximum normal altitude is 12,000 feet (3,660 meters).
Safety Certifications
UL, CUL, CSA, CE, CB, Austel
EMI Certifications
FCC Part 15 class B, VCCI, CTIC, BSMI, CE
Connectors
The RJ-45 twisted-pair ports are compatible with the IEEE 802.3 Type 10/100
Base-T standard. The following table displays media type and distance for these
connectors.
Status LEDs
The status LED indicates the operation of the NS-IDP-BYP device.
Temperature
Operating
Normal altitude
0
°
-40
°
C, 32-105
°
F
Relative humidity
10-90%
Non-condensing
10-90%
Standard
Media Type
Mhz/Km Rating Maximum Distance
100Base-TX
Category 5 and higher
Unshielded Twisted Pair
(UTP) Cable
100 meters
Status LED
Operation
Blinking Green
Bypass unit is passive (NetScreen-IDP appliance is up)
Blinking Orange