QuickStart Guide, Juniper Networks NetScreen-IDP 3.0 | 15
2. Change the IP address of the standalone computer to
192.168.1.2
.
For instructions on changing your IP address, see your computer’s
operating system documentation.
3. On the connected computer, open a Web browser. Enter the URL of the
ACM wizard as
https://192.168.1.1
. Because the ACM uses a
secure form of HTTP, you
MUST
enter
https://
before the IP address.
4. Enter the default user name (
root
) and password (
abc123
).
When the ACM wizard appears, proceed to “Configure the IDP Sensor”
on page 17.
Using a Serial Console or Keyboard/Monitor
1. Connect to the IDP appliance:
– For serial console connections, connect a serial console to the IDP
appliance Serial port and configure the terminal software to use
parameters 8-N-1, 9600. For Windows, use HyperTerminal. For
Linux, use minicom.
– For keyboard and monitor connections, connect a keyboard and
monitor to the IDP appliance.
2. Log in to the IDP appliance as
root
with the password
abc123
.
The Ethernet configuration script automatically runs. Follow the
instructions in the script’s help text to configure Ethernet access to the
IDP appliance.
3. When prompted, select the network card you want to configure. The
default configuration for that network card appears.
– To accept the default configuration, type
n
and press
Enter
to
continue.
– To reconfigure the network card, type
y
. Assign an IP address and
netmask to the network card. Be sure to use an IP address that is
reachable by the computer you will use to configure the Sensor
software. Press
Enter
to continue.
4. When prompted, set a default route by pressing
y
. Enter the default
route for the computer that you will use to configure the Sensor
software. Press
Enter
.