o
Switch on the service functions. To do so, briefly press the
Ƌ
and
ƌ
buttons simulta-
neously.
LED lights up red. The service functions are switched on.
o
Save luminaires or connections in the buffer memory of the transmitter, see Chapter 5.2,
5.3 or 5.4.
o
Pass on luminaires or connections to a transmitter, see Chapter 5.5.
i
If the above buttons are pressed again, or after 2 minutes without action, the service func-
tions are switched off and the buffer memory is deleted.
5.2 Registering selected luminaires
o
Switch on the service functions, see Chapter 5.1.
o
Press the
Ɔ
and
ƌ
buttons simultaneously until the LED flashes green.
LED lights up green for 3 seconds: the connection to the luminaire is saved in the buffer
memory. The transmitter is waiting for further connections.
LED flashes red rapidly for 3 seconds: the connection to the luminaires has not been saved
in the buffer memory. The transmitter is waiting for further connections.
o
Optionally save further connections to the buffer memory. To do so, repeat the previous
step.
o
Optionally press the
Ɔ
button briefly to show all luminaires present in the buffer memo-
ry.
The luminaires saved in the buffer memory light up briefly.
o
Within 2 minutes after the last button has been pressed, transfer the buffer memory to the
desired transmitter, see Chapter 5.5.
11/15
ZigBee radio hand-held transmitter
82595215
J0082595215
28.06.2017