Figure 2: Connection example
i
Ensure that the control cable is of the appropriate type, cross-section and routing for the
VDE specifications for 250 V cable, control voltage has basic insulation.
i
The control cable and load cable can be run in a shared cable, e.g. NYM J 5×1.5.
o
Connect actuator (5) and 1-10 V ballasts (6) as shown in the connection example
(figure 2). At the same time, note the information given by the manufacturers of the ballast.
o
If multiple circuit breakers supply dangerous voltages to the device or load, couple the
miniature circuit breakers or label them with a warning, to ensure disconnection is
guaranteed.
o
Insert the actuator in the appliance box in such a way that the
Prog
button (2) and status-
LED (3) are visible.
Figure 3: Operating mode switch
Position
Description
PC
Operating mode, parameter set with eNet
server *)
G
1-10 V operation
min.
Setting of the minimum brightness
*)
If the operating mode switch is turned from the position PC, the operating mode and
parameters are set to the default setting. The settings made with the eNet Server will be
lost.
o
Set the operating mode switch (1).
3/12
82581023
J0082581023
29.03.2017
eNet radio push-button controller 1-10 V 1-gang mini