Figure 2: Connection example

i

Ensure that the control cable is of the appropriate type, cross-section and routing for the
VDE specifications for 250 V cable, control voltage has basic insulation.

i

The control cable and load cable can be run in a shared cable, e.g. NYM J 5×1.5.

o

Connect actuator (5) and 1-10 V ballasts (6) as shown in the connection example
(figure 2). At the same time, note the information given by the manufacturers of the ballast.

o

If multiple circuit breakers supply dangerous voltages to the device or load, couple the
miniature circuit breakers or label them with a warning, to ensure disconnection is
guaranteed.

o

Insert the actuator in the appliance box in such a way that the 

Prog

 button (2) and status-

LED (3) are visible.

Figure 3: Operating mode switch

Position

Description

PC

Operating mode, parameter set with eNet
server *)

G

1-10 V operation

min.

Setting of the minimum brightness

*)

If the operating mode switch is turned from the position PC, the operating mode and
parameters are set to the default setting. The settings made with the eNet Server will be
lost.

o

Set the operating mode switch (1).

3/12

82581023
J0082581023

29.03.2017

eNet radio push-button controller 1-10 V 1-gang mini

Summary of Contents for FMST50UP

Page 1: ...t suitable for disconnection from supply voltage These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Device components 1 Operating...

Page 2: ...eading of error memory Response after mains voltage return The response after mains voltage return can be configured with the eNet Server Default setting Off 4 Operation Operation with radio transmitt...

Page 3: ...to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way that the Prog b...

Page 4: ...r are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter takes place Scene buttons must b...

Page 5: ...n be saved with a radio transmitter e g wall transmitter 6 Appendix 6 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby power max 0 5 W Ambient temperature 25 70 C Contact type...

Page 6: ...are ignored Advanced device settings Parameters Setting options Basic setting Explanations Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel Note In the...

Page 7: ...ll remain off Note The set time apply to operation using radio transmitters The device is switched immediately when the Prog button is pressed Switch off delay 0 s 24 h Basic setting 0 s The load swit...

Page 8: ...run on time On Off Basic setting Off Allows manual switch off of a running run on time If the parameter is switched off then a switch off command will also switch the actuator on Only visible if a run...

Page 9: ...ightness value as scene value in an actuator for a command via a transmitter Switch off warning On Off Basic setting Off If the switch off warning is active then during switch off the systems dims to...

Page 10: ...r the channel Activate wind alarm brightness value 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind alarm Deactivate wind alarm brightness value 0 100 Basic setting 0 D...

Page 11: ...h off on brightness overshoot Note This parameter is not yet active as a light controller has not yet been implemented Hotel function On Off Basic setting Off If the hotel function is activated the sy...

Page 12: ...rver for rail mounting Art No ENET SERVER 6 5 Conformity Albrecht Jung GmbH Co KG hereby declares that the radio system type Art No FMST50UP corresponds to the directive 2014 53 EU You can find the fu...

Reviews: