Scene operation possible
-
Status indicator of the 1-10 V subscribers via LED
-
Status feedback to radio transmitter
-
1-10 V subscribers switchable with
Prog
button
-
1-10 V interface is protected against reverse polarity
Can be set with eNet server:
-
Maximum brightness
-
Dimming speed
-
Switch-on delay / switch-off delay
-
Dim up/dim down ramp
-
Switch-off warning
-
Operation locks
-
Continuous on, Continuous off
-
Hotel function
-
Run-on time
-
Light control
i
If settings are changed with the eNet server, operation and signalling could vary from what
is described here.
i
The parameter list is in the Internet in the documentation for this device.
Supplementary functions with eNet server:
-
Update of the device software
-
Repeater function
-
Reading of error memory
Response after mains voltage return
The response after mains voltage return can be configured with the eNet Server. Default
setting: Off.
4 Operation
Operation with radio transmitters
Operation is with radio transmitters, please observe the radio transmitter instructions.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Mounting and connecting actuator
To ensure good transmission quality, keep a sufficient distance from any possible sources of
interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or
transformers.
2/12
82581023
J0082581023
29.03.2017
eNet radio push-button controller 1-10 V 1-gang mini