Local Operation
On, Off
Basic setting: On
Blocks the output for operation
using the
Prog
button.
Behaviour on voltage return
On
Off
Last value
Configured brightness
Basic setting: Off
Defines the behaviour of the
output after voltage return.
Brightness on voltage return
0...100 %
Basic setting: 100 %
Brightness value, set by the
output after voltage return
(mains voltage). The
parameter "Behaviour after
voltage return" must be set to
"Configured position".
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.
Behaviour after the end of the
disabling function
On
Off
no change
Last value
Basic setting: No change
Behaviour of the output when
a block is removed.
Manual saving of the scene
values
On, Off
Basic setting: On
Disables the saving of the
current brightness value as
scene value in an actuator for
a command via a transmitter.
Switch-off warning
On, Off
Basic setting: Off
If the switch-off warning is
active, then, during switch-off,
the systems dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down
operation, another command
is given, e.g. switch on or
scene recall, then the switch-
off warning stops and the
command is executed. A
switch-off command restarts
the time for the switch-off
warning.
Note: The set time apply to
operation using radio
transmitters. The device is
switched immediately when
the
Prog
button is pressed.
Priority, lock-out protection
0...4
Basic setting: 1
Specifies the priority for
recalling and removing a
scene of type Lock-out
protection for the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority.
9/12
82581023
J0082581023
29.03.2017
eNet radio push-button controller 1-10 V 1-gang mini