Local Operation

On, Off
Basic setting: On

Blocks the output for operation
using the 

Prog

 button.

Behaviour on voltage return

 On
 Off
Last value
Configured brightness
Basic setting: Off

Defines the behaviour of the
output after voltage return.

Brightness on voltage return

0...100 %
Basic setting: 100 %

Brightness value, set by the
output after voltage return
(mains voltage). The
parameter "Behaviour after
voltage return" must be set to
"Configured position".
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.

Behaviour after the end of the
disabling function

 On
 Off
no change
Last value
Basic setting: No change

Behaviour of the output when
a block is removed.

Manual saving of the scene
values

On, Off
Basic setting: On

Disables the saving of the
current brightness value as
scene value in an actuator for
a command via a transmitter.

Switch-off warning

On, Off
Basic setting: Off

If the switch-off warning is
active, then, during switch-off,
the systems dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down
operation, another command
is given, e.g. switch on or
scene recall, then the switch-
off warning stops and the
command is executed. A
switch-off command restarts
the time for the switch-off
warning.
Note: The set time apply to
operation using radio
transmitters. The device is
switched immediately when
the 

Prog

 button is pressed.

Priority, lock-out protection

0...4
Basic setting: 1

Specifies the priority for
recalling and removing a
scene of type Lock-out
protection for the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority. 

9/12

82581023
J0082581023

29.03.2017

eNet radio push-button controller 1-10 V 1-gang mini

Summary of Contents for FMST50UP

Page 1: ...t suitable for disconnection from supply voltage These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Device components 1 Operating...

Page 2: ...eading of error memory Response after mains voltage return The response after mains voltage return can be configured with the eNet Server Default setting Off 4 Operation Operation with radio transmitt...

Page 3: ...to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way that the Prog b...

Page 4: ...r are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter takes place Scene buttons must b...

Page 5: ...n be saved with a radio transmitter e g wall transmitter 6 Appendix 6 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby power max 0 5 W Ambient temperature 25 70 C Contact type...

Page 6: ...are ignored Advanced device settings Parameters Setting options Basic setting Explanations Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel Note In the...

Page 7: ...ll remain off Note The set time apply to operation using radio transmitters The device is switched immediately when the Prog button is pressed Switch off delay 0 s 24 h Basic setting 0 s The load swit...

Page 8: ...run on time On Off Basic setting Off Allows manual switch off of a running run on time If the parameter is switched off then a switch off command will also switch the actuator on Only visible if a run...

Page 9: ...ightness value as scene value in an actuator for a command via a transmitter Switch off warning On Off Basic setting Off If the switch off warning is active then during switch off the systems dims to...

Page 10: ...r the channel Activate wind alarm brightness value 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind alarm Deactivate wind alarm brightness value 0 100 Basic setting 0 D...

Page 11: ...h off on brightness overshoot Note This parameter is not yet active as a light controller has not yet been implemented Hotel function On Off Basic setting Off If the hotel function is activated the sy...

Page 12: ...rver for rail mounting Art No ENET SERVER 6 5 Conformity Albrecht Jung GmbH Co KG hereby declares that the radio system type Art No FMST50UP corresponds to the directive 2014 53 EU You can find the fu...

Reviews: