Minimum brightness

1...67 %
Basic setting: 5 %

Specifies the minimum
settable brightness.
Note: If parameters or scene
values are set to a level lower
than the minimum brightness,
then the system will dim to
minimum brightness.

Maximum brightness

75...100 %
Basic setting: 100 %

Specifies the maximum
settable brightness.
Note: If parameters or scene
values are set to a level higher
than the maximum brightness,
then the system will dim to
maximum brightness.

Dimming adjustment time

1…60 s
Basic setting: 4 s

Time from minimum
brightness until reaching
maximum brightness (dimming
speed).

Switch-on delay

0 s … 24 h
Basic setting: 0 s

The load switches on after a
delay. Repeated switch-on
commands restart the delay
time. If the load has not yet
been switched on due to the
delay when a switch-off
command comes, then the
load will remain off.
Note: The set time apply to
operation using radio
transmitters. The device is
switched immediately when
the 

Prog

 button is pressed.

Switch-off delay

0 s … 24 h
Basic setting: 0 s

The load switches off after a
delay. Repeated switch-off
commands restart the delay
time. If the load has not yet
been switched off due to the
delay when a switch-on
command comes, then the
load will remain on.
Note: The set time apply to
operation using radio
transmitters. The device is
switched immediately when
the 

Prog

 button is pressed.

Dim up ramp

0 s … 24 h
Basic setting: 0 s

Time between switch-on and
reaching switch-on brightness.
The light is switched on at
minimum brightness and then
dimmed to the switch-on
brightness.
Only applies to switch-on with
transmitters (short operation).
If scenes are recalled or
switching uses logic modules,
the switch-on brightness is
approached using so-called
soft dimming (not
configurable).

7/12

82581023
J0082581023

29.03.2017

eNet radio push-button controller 1-10 V 1-gang mini

Summary of Contents for FMST50UP

Page 1: ...t suitable for disconnection from supply voltage These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 Device components 1 Operating...

Page 2: ...eading of error memory Response after mains voltage return The response after mains voltage return can be configured with the eNet Server Default setting Off 4 Operation Operation with radio transmitt...

Page 3: ...to the device or load couple the miniature circuit breakers or label them with a warning to ensure disconnection is guaranteed o Insert the actuator in the appliance box in such a way that the Prog b...

Page 4: ...r are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter takes place Scene buttons must b...

Page 5: ...n be saved with a radio transmitter e g wall transmitter 6 Appendix 6 1 Technical data Rated voltage AC 230 V Mains frequency 50 60 Hz Standby power max 0 5 W Ambient temperature 25 70 C Contact type...

Page 6: ...are ignored Advanced device settings Parameters Setting options Basic setting Explanations Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel Note In the...

Page 7: ...ll remain off Note The set time apply to operation using radio transmitters The device is switched immediately when the Prog button is pressed Switch off delay 0 s 24 h Basic setting 0 s The load swit...

Page 8: ...run on time On Off Basic setting Off Allows manual switch off of a running run on time If the parameter is switched off then a switch off command will also switch the actuator on Only visible if a run...

Page 9: ...ightness value as scene value in an actuator for a command via a transmitter Switch off warning On Off Basic setting Off If the switch off warning is active then during switch off the systems dims to...

Page 10: ...r the channel Activate wind alarm brightness value 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind alarm Deactivate wind alarm brightness value 0 100 Basic setting 0 D...

Page 11: ...h off on brightness overshoot Note This parameter is not yet active as a light controller has not yet been implemented Hotel function On Off Basic setting Off If the hotel function is activated the sy...

Page 12: ...rver for rail mounting Art No ENET SERVER 6 5 Conformity Albrecht Jung GmbH Co KG hereby declares that the radio system type Art No FMST50UP corresponds to the directive 2014 53 EU You can find the fu...

Reviews: