V1.00/EN/00643259
Page 52/57
Data Sheet 406012
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
Email:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
Email:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
Email:
Internet: www.jumousa.com
40601200T10Z001K000
Remote mount design (sensor) – continued
(9)
Process connection
X X
11
Flange DIN PN 10
X X
12
Flange DIN PN 16
X X
14
Flange DIN PN 40
X X
20
Flange ASME CL150
X X
21
Flange ASME CL300
(10)
Process connection material
X X
01
Steel
X X
02
Stainless steel
a
(11)
Certificates
X X
1
Measuring pipe with PED approval
X X
3
Inspection certificate 3.1 according to EN 10204
X X
4
Pressure test according to AD2000
X X
5
Material certification 3.1 according to EN 10204 and pressure test according to AD2000
(12)
Calibration
X X
1
Standard accuracy
b
X X
2
Enhanced accuracy
c
(13)
Ambient temperature for sensor
X X
1
Standard transducer design/-20 to +60 °C (-4 to +140 °F)
d
(14)
Nameplate
X X
1
Adhesive label
X X
2
Stainless steel
X X
9
Others upon request
(15)
Signal cable length
e
X X
0
None
X X
1
5 m standard cable
X X
2
10 m standard cable
X X
3
20 m standard cable
X X
4
30 m standard cable
X X
5
50 m standard cable
X X
6
80 m standard cable
X X
7
100 m standard cable
X X
8
150 m standard cable
X X
9
Others upon request
(16)
Ex-zone
X
0
None
X
1
ATEX/IECEx zone 1
f
X
2
ATEX/IECEx zone 2/21
(17)
Protection type for sensor
X X
1
IP67 (NEMA 4X)
X X
2
IP68
g
a
See „Materials – sensor housing made of aluminum (shell housing) “, page 12
b
Standard accuracy (0.4 % of the measured value) includes 2 calibration points. If more than 2 calibration points are required, specify 3 or 5
points under "Number of test points".
c
Enhanced accuracy (0.2 % of the measured value) includes 3 calibration points. If more than 3 calibration points are required, specify 5 points
under "Number of test points". Available for DN10 (3/8
″
) to 300 (12
″
).
d
Maximum measurement medium temperature for sensor in standard design:
130 °C with PTFE, 90 °C with hard rubber.
e
For the model 406018/2-1 in the version for Ex-zone 1, 10 m (32.81 ft) cables are permanently connected to the transmitter. For maximum signal
cable lengths
see „Signal cable length and preamplifier “, page 11.
f
Only in conjunction with dual-compartment housing.
g
Only in conjunction with external transmitter.