V1.00/EN/00643259
Page 4/57
Data Sheet 406012
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
Email:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
Email:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
Email:
Internet: www.jumousa.com
40601200T10Z001K000
Model number
406012/1-0, 406012/1-1
Measured value deviation
Standard: 0.4 % of the measured value
Option: 0.2 % of the measured value
Nominal width range
DN 10 to 300 (3/8 to 12
″
) - Aluminium housing
DN 25 to 300 (1 to 12“) - Steel housing
Process connection
Flange according to DIN 2501/EN 1092-1, ASME B16.5
Nominal pressure
PN 10, PN 16, PN 40, ASME CL150, ASME CL300
Lining
Hard rubber: DN 15 to 300 (1/2 to12
″
) - Aluminium housing
Hard rubber: DN 40 to 300 (1 1/2 to12
″
) - Steel housing
PTFE: DN 10 to 300 (3/8 to 12
″
) - Aluminium housing
PTFE: DN 25 to 300 (1 to 12
″
) - Steel housing
Conductivity
> 5 µS/cm, (20 µS/cm for demineralized water)
Electrodes
Stainless steel, Hastelloy C, platinum-iridium, tantalum, titanium
Process connection material
Steel, stainless steel
Protection type
IP65, IP67 (NEMA 4X)
Medium temperature
Hard rubber: -15 to +90 °C (-5 to +194 °F)
PTFE: -25 to +130 °C (-13 to +266 °F)
Approvals
Electromagnetic compatibility
2004/108/EC – EMC (until April 19, 2016)
2014/30/EU – EMC (as of April 20, 2016)
Ex-protection
94/9/EC – ATEX (until April 19, 2016)
2014/34/EU – ATEX (as of April 20, 2016)
IECEx
Pressure equipment -
97/23/EC (until July 18, 2016 - Mod. B+D)
Conformity assessment acc. to
2014/68/EU (as of June 1, 2015 - Art. 13)
Category III, Fluid group 1
2014/68/EU (as of July 19, 2016 - Mod. B+D)
Transmitter
Voltage supply
AC 100 to 230 V (-15/+10 %), AC 24 V (-30/+10 %), DC 24 V (-30/+30 %)
Current output
4 to 20 mA active or passive
Pulse output
Active or passive can be set using software on-site
Switching output
Optocoupler, programmable function
Switching input
Optocoupler, programmable function
Display
Graphical display, adjustable
Housing
Compact design, available as single-compartment or dual-compartment housing, depending on
the requirements concerning the Ex-protection
Communication
HART protocol (standard), PROFIBUS-PA (option)
Electrical safety
According to DIN EN 61010-1
Electromagnetic compatibility
According to DIN EN 61326-1, DIN EN 61326-2-3