59
-
8-2. List of the memory switch functions
Various operations of the sewing machine can be set by programming the memory switch.
The initial setting values at the time of shipment differ with models.
No.
Function
Setting range State when delivered
Remarks
U001
Max. sewing speed
(Speed can be set in a unit of 100 sti/min.)
400 to 2700
2700
U002
Sewing speed of 1st stitch
(Speed can be set in a unit of 100 sti/min.)
400 to 1500
400
U003
Sewing speed of 2nd stitch
(Speed can be set in a unit of 100 sti/min.)
400 to 2700
900
U004
Sewing speed of 3rd stitch
(Speed can be set in a unit of 100 sti/min.)
400 to 2700
2700
U005
Sewing speed of 4th stitch
(Speed can be set in a unit of 100 sti/min.)
400 to 2700
2700
U006
Sewing speed of 5th stitch
(Speed can be set in a unit of 100 sti/min.)
400 to 2700
2700
U009
Changeover of tension releasing timing at the time
of thread trimming
−
6 to 4
4
U016
Disk floating timing at the beginning of sewing
−
10 to 2
−
5
U019
Selection of pedal
: Standard pedal
: Standard pedal (2-step stroke)
: Optional pedal
: Optional pedal (2-step stroke)
-
U020
Selection of start pedal
: Standard pedal
: Optional pedal
-
U024
Optional pedal 1 operation
: OFF when depressing pedal again
:OFF when detaching from pedal
-
U025
Optional pedal 2 operation
OFF when depressing pedal again
OFF when detaching from pedal
-
U026
Height of work clamp foot at the time of 2-step
stroke
50 to 90
70
Height is lowered
when the set value
is increased.
U030
Selection of base point of pattern enlargement/reduction
: Origin
: Sewing start point
-
U031
Sewing machine operation can be stopped with panel key (clear key).
: Ineffective
: Panel RESET key
: External switch
-
U032
Buzzer sound can be prohibited.
:
Without buzzer sound
: Panel operation sound
: Panel operation sound + error sound
-