70
-
Error code Indication
Description of error
Corrective measure
Remarks
E405
Prohibition of deletion of direct pat-
terns
The direct pattern is set in the cycle sew-
ing data.
Re-operation is enabled after
resetting.
E408
Password reset error
Wrong password has been entered.
Re-operation is enabled after
resetting.
E430
Counter set-value is reached
The set value of the counter is reached.
* For the type of counter and the counter
value displayed depends on the prede-
termined counter.
Re-operation is enabled after
resetting.
E730
Encoder trouble A
Encoder A or B phase cannot be detected.
Turn OFF the power switch.
Check whether the pin CN15
has come off or has loos-
ened.
E731
Encoder trouble B
Encoder U, V or W phase cannot be de-
tected.
Turn OFF the power switch.
Check whether the pin CN15
has come off or has loos-
ened.
E733
Reverse rotation of motor
The motor is reversing.
Turn OFF the power switch
and check whether coupling
of the main motor is loose.
E811
Overvoltage error
Power source voltage is beyond the speci-
fied value.
Check the power supply volt-
age.
E813
Low voltage error
Power source voltage is short.
Check the power supply volt-
age.
E901
Motor driver trouble
Error from the motor driver is detected.
Turn OFF the power switch
and turn ON the power switch
again after some time.
E903
Stepping motor power supply trouble
Power source of the stepping motor is not
output.
Turn OFF the power switch
and check F1 fuse of SDC
board.
E904
Solenoid power supply trouble
Power source of the solenoid is not out-
put.
Turn OFF the power switch
and check F2 fuse of SDC
board.
E905
SDC board overheat
Overheat of SDC board
Turn OFF the power switch
and turn ON the power switch
again after some time.
E907
X origin retrieval error
X origin sensor does not change.
Turn OFF the power switch
and check whether CN42
and/or CN53 of the MAIN
board are disconnected or
loose.