69
-
Error code Indication
Description of error
Corrective measure
Remarks
E043
Enlargement error
The sewing pitch is beyond 10 mm.
Press the reset key and
check the pattern and X/Y
scale rate.
E045
Pattern data error
The pattern data cannot be adopted.
Re-operation is enabled after
resetting.
E050
Temporary stop
Temporary stop by operating the reset
key while the sewing machine is running.
(Refer to memory switch No. 31.)
Re-start or return-to-ori-
gin after thread trimming
by means of the reset key
(For the details, refer to the
item
.)
E061
Memory switch data error
Memory switch data is broken or revision
is old.
Re-operation is enabled after
resetting.
E063
Machine head identification error
The type of machine head and the type of
control box do not match.
Turn the power OFF and
contact JUKI or your distribu
-
tor.
E204
Connection alert for the USB thumb
drive which is used for sewing
Sewing has been carried out by 10 or
more times with the USB thumb drive in-
serted in the USB port.
Re-operation is enabled after
resetting.
E220
Grease replenishing time information
Information as to the time of replenishing
the designated places with grease
Refer to
"I.7-9. Replenishing the desig-
nated places with grease" p.56
Replenish the designated
places with grease and set
memory switch No. 245 to
“0” with the RESET key. Er-
ror can be released with the
RESET key when immediate
replenishing with grease
cannot be performed during
sewing operation.
E221
Grease replenishing warning error
Sewing machine has stopped since the
time of replenishing the designated plac-
es with grease has come.
Refer to
"I.7-9. Replenishing the desig-
nated places with grease" p.56
Immediately perform replen-
ishing with grease and set
memory switch No. 245 to “0”
with the RESET key.
E302
Head tilt error
Head tilt detection switch is turned OFF.
The sewing machine cannot
be operated with the head
tilted. Return the sewing
machine head to its proper
position.
E303
Z phase detection error
Detection of the upper dead point of the
sewing machine cannot be performed.
Turn OFF the power switch.
Check whether the pin of the
SDC board CN15 has come
off or has loosened.
E305
Thread trimmer position error
The thread trimmer is not in the proper
position.
Turn OFF the power switch
and check whether CN72
has come off or has loos-
ened.