10
-
7 .
Attaching Other Supplied Parts
(1) Signal Light
a) Insert the signal light through the upper hole of the cover RUR.
b) Locate the supplied nuts and w ashers as indicated in Figure 7.2, then fix them on
the bracket. Connect the connector to the bracket.
After installing the signal light, adjust its height so that the distance
from the floor to the upper surface of the signal light can be 2,000 mm
(2,050 mm if installing the machine abroad).
(2) Vision Monitor
a) Insert the power code of the vision monitor from the hole in the middle of the monitor
base to the main unit, then fix the top of the vision monitor on the monitor base.
Make sure that the protruded part of the monitor top is hooked over
the knob of the monitor base.
b) Pull out the image monitor cable from the rear of the monitor top, then connect it to
the VIDEO IN jack.
c) C onnect the pow er code connector to the pow er relay cable at the rear side of the
panel computer.
CAUTION
!
CAUTION
!
Vision
monitor
Signal light
Cover RUR
Figure 7.2
Figure 7.1
Monitor base
Knob
Image monitor cable
Figure 7.3