– 34 –
(8) Adjustment of the amount of feeding
8) Installation of the reverse feed arm and the reverse feed solenoid
Standard Adjustment
0.5 to 1.0mm
9) Stop position of the feed control spring rack
Install the feed control spring rack
(40086728) so that a distance of 2.3mm is kept between the oblong
hole end plane of the bed column B
and the end part of the setscrew
.
2.3mm
A
Details in Part A
Summary of Contents for DDL-9000B-DS
Page 14: ... 10 4 Feed locus and phase 1 Timing standard 2 Timing fast 3 Timing slow Standard Adjustment ...
Page 32: ... 28 8 Adjustment of the amount of feeding 4 Optional switch Standard Adjustment ...
Page 58: ... 54 11 Thread trimming unit 8 Replacement of the moving knife Standard Adjustment ...
Page 70: ... 66 12 Adjustment of the wiper DDL 9000B WB 2mm 1mm Standard Adjustment ...
Page 112: ...MEMO ...